11. SNMP

This section overviews the SNMP V2c northbound Trap and southbound GET functionality supported by the ASM products
using baseline 2.8 (and above) firmware. SNMP Community String value configuration and supporting SNMP Managers
that require non 'null' returned values is available in baseline 2.8.3 (and above) firmware.
The Antenna System Monitor (ASM) SNMP Interface is defined by the following MIB files:
RF-INDUSTRIES-MIB.txt
RFI-AXM-ALARM-MIB.txt
The RFI-AXM-ALARM-MIB file provides details of the various objects (OIDs) within every trap that is sent whenever an
alarm status change occurs.
The axmAlarmType object (1.3.6.1.4.1.32327.2.2.2.1.2.3) defines 11 different types of traps.
Every trap includes the following objects:
Trap Objects
axmAlarmCustName
OID 1.3.6.1.4.1.32327.2.2.2.1.2.1
Syntax Text String
Description
axmAlarmSiteName
OID 1.3.6.1.4.1.32327.2.2.2.1.2.2
Syntax Text String
Description
axmAlarmType
OID 1.3.6.1.4.1.32327.2.2.2.1.2.3
Syntax Integer 0..5
Description
Restart (0)
SystemStatus (1)
ChannelStatus (2)
CamStatus (3)
AccessEvent (4)
IsolTestStatus (5)
Updated MIB files are available for download.
Provides the Customer Name string as configured on the User Data Configuration page.
Provides the Site Name string as configured on the User Data Configuration page.
Identifies the type of alarm that this trap relates to. The data for some of the other objects will
depend on the alarm type.
The possible Types (and integer values) are:
The unit has just been restarted.
The summary alarm status has changed.
An individual channel alarm status has changed.
An Alarm Module input alarm status has changed.
Three or more consecutive login attempts have failed, resulting in a lockout state.
A change in Isolation test alarm status.