Service Manual - VMH 9/12/18/24 SU & VMH30/36S D Series
2) Pull out the two blue
wires connected with
the four way valve.
3) Pull out connectors of
the condenser coil
temp. sensor (T3),
outdoor ambient temp.
sensor (T4) and
discharge temp.
sensor (TP).
4) Disconnect the
electronic expansion
valve wire.
○
○
○
4
67
70
○
2
2
○
3
3