  • Page 1 Product Manual WDC100 Electronic Control For Basins/Baths, Showers and WCs...
  • Page 2 Product Manual Solid Surface WC Pans Product Manual WDC100 Electronic Control AS 1172 RCM Mark Certificate No Australia 23167 Revision 15...
  • Page 3: Table Of Contents

    Hygiene Purge ........................18 5.6.7. Data Logging ......................... 18 5.6.8. Auto-Run ..........................19 5.7. Technical Specifications ........................ 19 User and Maintenance Instructions ....................20 6.1. Operation ............................20 6.2. Maintenance ..........................22 WDC100 Menu Settings ........................ 23 Related Documentation ......................... 29 Revision 15...
  • Page 4: Disclaimer & Copyright Notice

    Every effort has been made to supply information within this manual which is correct. Wallgate Limited will not be liable for any damage or loss that arises if the person installing, operating or maintaining the unit has not read or not complied with the manual In any event, and without prejudice to any warranties in Wallgate Limited’s terms and...
  • Page 5: Conventions

    A warning with red text on a white background is used to give information about hazards that can cause injury or death. Read and understand the warnings before you install and commission the WDC100. Failure to heed these warnings can have serious consequences.
  • Page 6: Glossary

    Activations of the Hygiene Purge function detailed below are logged in memory and then using additional software the logs can be downloaded from the WDC100 and imported into a spreadsheet report. Dual Flush This option is used when both full and half flush options must be provided, using either one or two piezo touch buttons.
  • Page 7 The RJ-45 connectors are used to connect the WDC unit to a PC or laptop. Real Time Clock. This is a 24 hour 7 day clock used by the WDC100 for program features such as Time Slots and Hygiene Purge. System Test...
  • Page 8: Product Summary

    The WDC100 series electronic control units are designed to operate the water outlets (x1) (Hot and Cold), to a wash basin (or a bath model WDC100-1), a shower (x1) (premixed warm water) and the flush for toilet water closet pan (x1) (WC).
  • Page 9: Installation And Commissioning

    5. Installation and Commissioning 5.1. Package Contents Before you begin the installation, make sure that you have the following items:  1 WDC100 Electronic control unit (or WDC100-1 bath model)  1 Product manual. 5.2. Site Preparation 5.2.1. Advice on attaching the unit ...
  • Page 10: Attach The Controller Unit

    Use suitable wall plugs if necessary. Attach the unit to the wall using four round head screws. NOTE: When mounting the unit, make sure the cable sockets at the bottom of the unit point downwards. Figure 1. WDC100 Lower Panel Item No. Description Function Water Valve Cable Sockets Output to WC, shower and washbasin (or bath) water valves.
  • Page 11: Connect The Input And Output Cables

    Connect the Input and Output Cables The control unit has input and output sockets in the lower panel of the unit. Refer to Figure 2 for the illustration of the lower panel. Figure 2.Connectors in the WDC100 control unit Item Description...
  • Page 12: Connect The 3 Pin Connector

    All inputs are volt free normally open contacts. Close input to activate the function. +12v is available to power the infrared sensors on the middle (ring) contact. Input switch cables with fitted 3.5mm stereo jack plugs are available from Wallgate, please contact sales if required. Revision 15...
  • Page 13: Connect The Electrical Supply

    5.5. Connect the Electrical Supply To make the electrical connections to the control unit: WARNING! The electrical connections must be made by a qualified electrical engineer in accordance with the present nationally approved IEE Regulations. Terminate the supply cable from the control unit into the spur connection outlet and fit a 2 Amp fuse.
  • Page 14: Commission The Unit

    5.6. Commission the Unit All the switches and the menu display is located on the front panel of the WDC100 control unit. Refer to Figure 3 below for an illustration of the WDC100 front panel. Valve Menu Down Return /...
  • Page 15: Lockout Function

    To stop the cycle, switch off the electrical supply to the electronic control unit. Correct any problems such as blockages before you run the purge cycle again. The control unit has various function settings that can be enabled or disabled. The settings are given in section 7, WDC100 Menu Settings. 5.6.2. Lockout function The Lockout function restricts the number of usages for the basin/bath, shower and WC.
  • Page 16: Piezo Touch Button And Infrared Sensor Controls

    Check that the basin/bath, shower and WC are operating correctly. An option to connect a switch to an auxiliary input that is set for Reset Lockout is available, contact Wallgate for additional information. 5.6.3. Piezo touch button and infrared sensor controls Piezo touch buttons and infrared sensors can be connected to the control unit to operate the basin/bath, shower and WC.
  • Page 17: System Test Function

    To test the operation of the piezo and infrared sensors: Operate each button or sensor and observe that they work correctly. The hot and cold basin valves are set to open for 10 seconds each, (bath = 180s). The shower valve is set to open for 60 seconds. The WC flush valve is set to deliver a 6 litre flush.
  • Page 18: Product Time Slots

    Data logging records the events of the hygiene purge operations. The data log records can then be downloaded from the WDC100 to a PC or laptop. The download data is in the form of a csv file. Additional software is required from Wallgate to perform the download and also create data log reports.
  • Page 19: Auto-Run

    Wallgate sales office. 5.6.8. Auto-Run  The Auto-Run function allows any output to automatically open at a set time every day. There are 48 off half hourly time activation settings available for each output.
  • Page 20: User And Maintenance Instructions

    The electronic control unit has been designed and manufactured from good quality materials. If these instructions are followed, the unit will give reliable, efficient service. If you need any further information or advice, please contact Wallgate customer services. 6.1. Operation Use the main isolation switch provided by the installer to switch the unit on or off.
  • Page 21 A few important settings and their default states are given in Table 4. Setting Name Default State Description Exclusivity Disabled This prevents more than one outlet being operated at a time. Water Lockouts Disabled See Table 5 on page 23 for more information on this setting.
  • Page 22: Maintenance

    Any service or repair work must be carried out by a qualified engineer. During the warranty period, the service or repair must only be done by a Wallgate engineer or appointed service agent. Refer to the Wallgate Limited’s terms and conditions for warranty information.
  • Page 23: Wdc100 Menu Settings

    Press the key to select a menu item, or to modify a setting. Press the key to navigate up the menu tree by one level. Table 5. WDC100 Menu Settings Default Main Menu Item Sub Menu 1 Sub Menu 2...
  • Page 24 Default Main Menu Item Sub Menu 1 Sub Menu 2 Available Options Value Cell Water Settings Basin cold outlet run Basin Cold Cycle 1 to 999 Seconds time Time Seconds Basin hot outlet run Basin Hot Cycle 1 to 999 Seconds time Time Seconds...
  • Page 25 Default Main Menu Item Sub Menu 1 Sub Menu 2 Available Options Value Cell Time Slots Specify the timings for Time Slot 1 Start 00:00 to 23:00 00:00 4 Basin Time Slots. Time Slot 1 End 00:00 to 23:00 06:00 Reset the Time Slots.
  • Page 26 Default Main Menu Item Sub Menu 1 Sub Menu 2 Available Options Value Cell Hygiene Settings Specify the period for Basin Inactivity Off or 1 to 100 Days basin inactivity. Period Specify the period for Basin Purge Time 1 to 999 Seconds purging the basin.
  • Page 27 Auto Run default settings: Main Menu Item: Auto-Run Cycle Water Outlets Room 1 3 – 4 – TIME SHWR BASIN BASIN (Cold) (Hot) 06:00 06:30 07:00 07:30 08:00 08:30 09:00 09:30 10:00 10:30 11:00 11:30 12:00 12:30 13:00 13:30 14:00 14:30 15:00 15:30...
  • Page 28 Main Menu Item: Auto-Run Cycle Water Outlets Room 1 3 – 4 – TIME SHWR BASIN BASIN (Cold) (Hot) 21:00 21:30 22:00 22:30 23:00 23:30 00:00 00:30 01:00 01:30 02:00 02:30 03:00 03:30 04:00 04:30 05:00 05:30 The default setting for the auto-run function is N = OFF on all outlets for all time settings. Changing the default to Y will set that outlet to switch ON at that time setting.
  • Page 29: Related Documentation

    8. Related Documentation  Product Manual for WDCMS optional software for networking WDC units to a PC or laptop.  Product Manual for Data Logging optional software for downloading hygiene purge activation logs from the WDC control units and creating log reports. Revision 15...
  • Page 30 Wallgate Ltd. Crow Lane, Wilton, Salisbury, Wiltshire, SP2 0HB, England tel: +44 (0) 1722 744594 fax: +44 (0) 1722 742096 email: service@wallgate.com web: www.wallgate.com Revision 15...