attika VIVA 100 L Classic Gas User Manual

Hide thumbs Also See for VIVA 100 L Classic Gas:
Table of Contents

Advertisement

Quick Links

V I VA L G A S
B R U G E R M A N U A L
B E D I E N U N G S A N L E I T U N G
U S E R M A N U A L
M A N U E L D ' U T I L I S AT E U R
B R U K E R V E I L E D N I N G
B R U K S A N V I S N I N G
K Ä Y T T Ö O H J E
G E B R U I K E R S H A N D L E I D I N G
POSITIV
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIVA 100 L Classic Gas and is the answer not in the manual?

Questions and answers

Summary of Contents for attika VIVA 100 L Classic Gas

  • Page 1 V I VA L G A S B R U G E R M A N U A L B E D I E N U N G S A N L E I T U N G U S E R M A N U A L M A N U E L D ’...
  • Page 2 Product ID: 0359CS1717 VIVA 100 L Gas / VIVA 100 L G Gas / VIVA 100 L Classic Gas / VIVA 100 L G Classic Gas VIVA 120 L Gas / VIVA 120 L G Gas / VIVA 120 L Classic Gas / VIVA 120 L G Classic Gas...
  • Page 3 This manual covers the following models: Viva 100 L Gas – without side glass Viva 100 LG Gas – with side glass Viva 100 L Classic Gas – without side glass Viva 100 LG Classic Gas – with side glass Viva 120 L Gas –...
  • Page 4: Table Of Contents

    English RAIS/ - User manual for VIVA L Gas Revision : Date 17-08-2017 INTRODUCTION �����������������������������������������������������������������������������������������������������������������5 GUARANTEE ���������������������������������������������������������������������������������������������������������������������������6 SPECIFICATIONS ���������������������������������������������������������������������������������������������������������������������7 DISTANCE/TEMPLATE ��������������������������������������������������������������������������������������������������������������7 GENERAL GENERAL REMARKS ���������������������������������������������������������������������������������������������������������������8 EMERGENCY INTERRUPTION OF GAS SUPPLY �������������������������������������������������������������������������9 INSTALLATION OF STOVE INSTALLATION ����������������������������������������������������������������������������������������������������������������������10 GAS CONNECTION ���������������������������������������������������������������������������������������������������������������10 VENTILATION ������������������������������������������������������������������������������������������������������������������������10...
  • Page 5 English RAIS/ - User manual for VIVA L Gas Introduction attika Good luck with your new RAIS/ Product� attika A RAIS/ stove is more than just a source of heat, it also expresses how you put the emphasis on good design and high quality in your home�...
  • Page 6: Guarantee

    English RAIS/ - User manual for VIVA L Gas Guarantee attika RAIS/ stoves are checked several times with regard to safety, as well as the quality of materials and manufacturing� We offer a guarantee on all models and the guarantee commences on the date of installation�...
  • Page 7: Specifications

    English RAIS/ - User manual for VIVA L Gas Specifications Viva 100 L Gas Viva 120 L Gas Viva 160 L Gas Intertek Ref�: 102929617LHD-001 Gas type G20 Gas type G20 Gas type G20 I2H/I2E I2H/I2E I2H/I2E Nominal heat output (kW): 9�1...
  • Page 8: General

    English RAIS/ - User manual for VIVA L Gas General General Comments attika This RAIS/ product is an extremely effective convection gas stove with a sealed combustion chamber for chimneys with a balanced draught� It is fitted with a burner with the latest burner technology�...
  • Page 9: Emergency Interruption Of Gas Supply

    English RAIS/ - User manual for VIVA L Gas Emergency interruption of gas supply Where a smell of gas is detected, the gas supply must be interrupted immediately� Ventilate the room by opening windows and doors, do not use electrical appliances in the vicinity of the stove�...
  • Page 10: Installation Of Stove

    English RAIS/ - User manual for VIVA L Gas installation of stove Installation It is important that the stove is correctly installed from both an environ- mental and safety point of view� The stove must only be installed by an authorised gas installer When installing the stove, all local rules and regulations, including those referring to national and European standards must be complied with�...
  • Page 11: Changing The Chimney Connection

    English RAIS/ - User manual for VIVA L Gas PLEASE NOTE! The floor construction must be able to bear the weight of the stove and chimney, if applicable� If the existing design does not satisfy this prereq- uisite, suitable measures must be taken (e�g�, a load distribution slab)�...
  • Page 12 English RAIS/ - User manual for VIVA L Gas 2� Loosen the three screws on the outer flange on the top sur- face of the stove� And remove it� 3� Loosen the three screws on the inner flange on the bottom surface of the stove�...
  • Page 13 English RAIS/ - User manual for VIVA L Gas 7� If the ceramic logs are fitted remove these� 8� The thin side pieces of the back plate are removed by loosening the two screws, one at the top and one at the bottom�...
  • Page 14: Conversion To Bottled Gas (Lpg)

    English RAIS/ - User manual for VIVA L Gas Conversion to bottled gas (LPG) The stove is supplied configured for natural gas but can be converted to bottled gas (LPG)� The conversion must only be carried out by an author- ised gas engineer�...
  • Page 15 English RAIS/ - User manual for VIVA L Gas The nozzle for the main burner for LPG is marked "80" The nozzle for the main burner for natu- ral gas is marked "120" The nozzle for the pilot light for LPG is marked "27"...
  • Page 16 English RAIS/ - User manual for VIVA L Gas The gas unit needs to be dismantled to gain access to the nozzles� Do this in the following manner: Lift the perforated plate up and out of the stove� Loosen the four screws holding the...
  • Page 17 English RAIS/ - User manual for VIVA L Gas Now the gas unit can be lifted out carefully by tilting and rotating the unit a little� Once the gas unit has been dismounted, replace the four nozzles and adjust the three air intakes�...
  • Page 18 English RAIS/ - User manual for VIVA L Gas Remove the nozzle for the main burner by loosening the coupling and carefully pulling the pipe out and then unscrewing the noz- zle� Fit the LPG nozzle and tighten the lock nut�...
  • Page 19 English RAIS/ - User manual for VIVA L Gas The air intake to the main burner is adjust- ed for LPG configuration by loosening the two nuts and pushing the plate all the way towards the burner� (The hole fully open)
  • Page 20 English RAIS/ - User manual for VIVA L Gas The air intakes need to be reversed therefore when the stove is config- ured for LPG� The gas unit is reassembled using the four screws� Replace the perforated plate and fully assemble the stove�...
  • Page 21: Normal Installation - Rectangular Without Side Glass

    English RAIS/ - User manual for VIVA L Gas Installation distance from flammable wall In order to clarify whether the wall your stove will stand alongside is flammable, you can contact your building architect or the local building authorities�...
  • Page 22: Normal Installation - Rectangular Without Side Glass

    English RAIS/ - User manual for VIVA L Gas Viva 100 L G Gas Normal installation - at right angle Viva 120 L G Gas With side glass Viva 160 L G Gas Uninsulated flue A� Furniture distance (min�) 800 mm Distance to flammable material (min�)
  • Page 23: Corner Installation 45° Without Side Glass

    English RAIS/ - User manual for VIVA L Gas Corner installation 45° Viva 100 L Gas Viva 120 L Gas Without side glass Viva 160 L Gas Uninsulated flue A� Furniture distance (min�) 850 mm Distance to flammable material (min�) D 75 D�...
  • Page 24: Corner Installation 45° With Side Glass

    English RAIS/ - User manual for VIVA L Gas Viva 100 L G Gas Corner installation 45° Viva 120 L G Gas With side glass Viva 160 L G Gas Uninsulated flue A� Furniture distance (min�) 800 mm D 75 Distance to flammable material (min�)
  • Page 25: Installation Spacing For Non-Flammable Wall

    English RAIS/ - User manual for VIVA L Gas Installation distance at non-flammable wall We recommend a minimum distance of 75m (F) to non-flammable material to allow service and installation� Where the outlet is to the rear, there should however be space for a measuring connection piece for combustion control�...
  • Page 26: Chimney/Vent

    English RAIS/ - User manual for VIVA L Gas Chimney/Flue This stove must be either installed with a ceiling terminal (C31) or a wall terminal (C11) Must only be installed with a flue with a balanced draught (also known as a concentric draft) as stated by RAIS�...
  • Page 27: Location Of Chimney Terminals

    English RAIS/ - User manual for VIVA L Gas Location of chimney terminals Distance (mm) Dimension Terminal Position Directly under an opening, an open window or ventilation duct Above an opening, an open window or ventilation duct Alongside an opening, opening window etc�...
  • Page 28: Horizontal Wall Terminal Type C11

    English RAIS/ - User manual for VIVA L Gas Horizontal Wall Terminal type C11 Dimension of outflow pipe: Viva L Ø100 / Ø150 Outlet connection piece on the stove Ø100 / Ø150 Can be used for the entire chimney, or, Ø130 / Ø200 Adapter can be used so that you can use...
  • Page 29: Vertical Roof Terminal C31

    English RAIS/ - User manual for VIVA L Gas Vertical roof terminal type C31 Dimension of outflow pipe: Viva L Ø100 / Ø150 Outlet connection piece on the stove Ø100 / Ø150 Can be used for the entire chimney, or, Ø130 / Ø200 Adapter can be used so that you can use...
  • Page 30: Assembly Of Secondary Burner

    English RAIS/ - User manual for VIVA L Gas Fitting of Secondary burners The burners are inserted above the pipes sticking through the perforated plate� Note that there is a right burner and a left one so it is important that they are posi- tioned as shown, i�e�, that the...
  • Page 31: Arrangement Of "Embers" And "Logs

    English RAIS/ - User manual for VIVA L Gas Arrangement of "Embers" and ”Logs" When layers of embers and the ceramic logs are arranged in the com- bustion chamber, it is important that the pilot flame and its thermosen- sor are not covered over�...
  • Page 32 English RAIS/ - User manual for VIVA L Gas ceramic "Logs Log 1 Log 2 Log 3 Log 4 Log 6 Log A Log 5 Log B...
  • Page 33 English RAIS/ - User manual for VIVA L Gas Positioning of Logs and Embers Spread the content of the bag of "Embers" as shown in the illustra- tion� Note: The pilot area must be kept clear of "Embers"� Position the 8 logs as shown�...
  • Page 34 English RAIS/ - User manual for VIVA L Gas Log 3 Log 4 Log 5...
  • Page 35 English RAIS/ - User manual for VIVA L Gas Log 6 Sample photos Log A Log B...
  • Page 36: Start-Up

    English RAIS/ - User manual for VIVA L Gas Start-up Insertion of Batteries. The receiver on the stove and the remote con- trol use batteries� A set of batteries to be inserted prior to start- up is included� To access the battery box on...
  • Page 37 English RAIS/ - User manual for VIVA L Gas The batteries in the receiver must face the directions shown in the illustration� The remote control uses 2 x AA 1�5 V batteries�...
  • Page 38: Setting Up The Electronic Code

    English RAIS/ - User manual for VIVA L Gas SETTING UP OF THE ELECTRONIC CODE In order for the remote control to work, it must be synchronised with the stove's receiver� A code is selected automatically from 65,000 possible codes�...
  • Page 39: Commissioning

    English RAIS/ - User manual for VIVA L Gas Commissioning Check functioning of pilot light. See User Instructions for use of remote control� 1� Start the pilot light� 2� Check that the pilot light remains ignited� 3� Turn off the pilot light�...
  • Page 40 English RAIS/ - User manual for VIVA L Gas...
  • Page 41: Initial Ignition

    English RAIS/ - User manual for VIVA L Gas Initial ignition For the initial ignition, ensure that all packaging, labels etc� have been removed from the stove and that the door glass has been cleaned� Begin at low output, then the stove can be slowly turned up to a great- er output�...
  • Page 42: User Instructions

    English RAIS/ - User manual for VIVA L Gas User instructions USER INSTRUCTIONS NOTE: When you press on a deactivated button, GENERAL NOTES nothing happens and two horizontal lines are dis- played� The wiring for valves and receiver must be closed off before...
  • Page 43 English RAIS/ - User manual for VIVA L Gas Signal control Child proofing Time Thermostatic mode Battery status Countdown timer Fahrenheit or Celsius Program mode Eco mode Temperature Help function SETTING OF FAHRENHEIT or CELSIUS CHILD PROOFING Change between °C and °F...
  • Page 44 English RAIS/ - User manual for VIVA L Gas HOW TO IGNITE IN STANDBY MODE (PILOT LIGHT) HANDSET •Press and hold down the button to set the appli- When pilot ignition is confirmed, the motor auto- ance to pilot light�...
  • Page 45 English RAIS/ - User manual for VIVA L Gas •High flame is activated Program mode by double-clicking on the button HI is displayed� PROGRAMS 1 and 2 can both be programmed to start or stop at specific times at a set temperature�...
  • Page 46 English RAIS/ - User manual for VIVA L Gas PROGRAM MODE SETTING THE DAY: 1 or 2, 5� ALL flashes� Press the Press the button ON or OFF is displayed� button to select from ALL, SA:SU, 1, 2, 3, 4, 5, 6, 7�...
  • Page 47 English RAIS/ - User manual for VIVA L Gas SA:SU or Daily Timer ( 1 , 2, 3, 4, 5, 6, 7) is select- • Set operating time and time for shut down by using the same approach as during "ALL selected" (above)�...
  • Page 48: Using Stove Without Remote Control

    English RAIS/ - User manual for VIVA L Gas Using stove without remote control. Where the remote control cannot be used, it is possible to turn on the stove manually� Always be very cautious if you chose to do this as the combustion chamber needs to be opened�...
  • Page 49 English RAIS/ - User manual for VIVA L Gas Once the pilot flame is ignited, turn the control button so that the arrow points down to (1) ON. Now the Main and secondary burners can be ignited and adjusted by turn- ing the gas valve anticlockwise above to (2) ON.
  • Page 50: Service

    English RAIS/ - User manual for VIVA L Gas Service. The stove should be inspected by a gas engineer once a year� As a minimum, this in- spection should ensure that the stove is working correctly and is safe to use�...
  • Page 51: Cleaning

    English RAIS/ - User manual for VIVA L Gas Cleaning It is advisable to clean the stove of dust and foreign bodies each new heating season and especially if the stove has not been used for a long time� This can be done with a soft brush and a vacuum cleaner�...
  • Page 52: Accessories

    English RAIS/ - User manual for VIVA L Gas Accessories 2796521 - 6KG heat accumulation stone for Viva 120 L, 4 in a set� 2710611SV - Stainless Classic Top plate for Rear outlet 2710612SV - Stainless Classic Top plate for Top...
  • Page 53: Myfire Wi-Fi Box

    English RAIS/ - User manual for VIVA L Gas Installation of MyFire Wi-Fi Box Viva L Gas can be controlled remotely via an APP for your smart phone or tablet� The MyFire Wi-Fi Box is connected to the Receiver, which is placed un- der the combustion chamber by opening the stove door and inserting the narrow plug on the Wi-Fi lead into the opening marked ”SI”�...
  • Page 54 English RAIS/ - User manual for VIVA L Gas CONFIGURATION OF THE MYFIRE APP CONFIRM THE SETTINGS FOR THE FIREPLACE When configuring the MyFire app you will need the 1� After confirming the settings for fireplace, touch SSID key and access code for the wireless network the "Finish"...
  • Page 55: Spare Part List Viva 100 L Gas - Viva 120 L Gas - Viva 160 L Gas

    English RAIS/ - User manual for VIVA L Gas Spare parts list: Viva 100 L gas - VIVA 120 L gas - VIVA 160 L gas If spare parts other than those recommended by RAIS are used, the guarantee will be invalidated�...
  • Page 56: Spare Part List Viva 100 L G Gas - Viva 120 L G Gas - Viva 160 L G Gas

    English RAIS/ - User manual for VIVA L Gas Spare parts list: VIVA 100 L G Gas - 120 L G Gas - 160 L G Gas If spare parts other than those recommended by RAIS are used, the guarantee will be invalidated�...
  • Page 57: Spare Part List Gas Unit

    English RAIS/ - User manual for VIVA L Gas Spare parts list: VIVA L Gas - Gas unit If spare parts other than those recommended by RAIS are used, the guarantee will be invalidated� All replaceable parts can be purchased as spare parts from your RAIS dealer�...
  • Page 58: Technical Information

    English RAIS/ - User manual for VIVA L Gas Technical Information Country Natural AT -Austria I2H, G20 at 20 mbar I3P(50),G31 at 50 mbar; I3B/ P(50),G30/G31 at 50 mbar BE -Belgium I2E+, G20/G25 at 20/25 I3+,G31/G31 at 28/37 mbar; I3P-...
  • Page 59 English RAIS/ - User manual for VIVA L Gas Country Natural GR -Greece I2H, G20 at 20 mbar I3+,G31/G31 at 28/37 mbar; I3P(37),G31 at 37 mbar; I3B/ P(30),G30/G31 at 30 mbar HU-Hungary I3B/P(30),G30/G31 at 30 mbar HR -Croa- I2H, G20 at 20 mbar I3P(37),G31 at 37 mbar;...
  • Page 60: Technical Data

    English RAIS/ - User manual for VIVA L Gas Technical Data Product Identification Number: 0359CS1717 Viva L Gas Gas type G20/G25 G25/G25.3 G20/G25 I2H,I2E I2E+ I2L/ I2EK I2ELL Supply Pressure mbar 20/25 Nominal Heat Input 9�1 9�1 / 8�4 8�5...
  • Page 61 English RAIS/ - User manual for VIVA L Gas Gas type G30/G31 G30/G31 I3B/P(30) I3P(50) I3P(37) I3P(30) Supply Pressure mbar 30 / 37 Nominal Heat Input Gross (Hs) Nominal Heat 7�4 7�4 7�4 7�4 7�4 Input Nett (Hi) Consumption m³/hr...
  • Page 62: Examples Of Chimney Solutions

    English RAIS/ - User manual for VIVA L Gas EXAMPLES OF CHIMNEY SOLUTIONS Vertical Roof Terminal Distance ”V” 500mm - 12m (min� - Max)
  • Page 63 English RAIS/ - User manual for VIVA L Gas Vertical Roof Terminal (PT 3 of 3) F (Flexible flue insert Ø100 AI- SA-316Ti) Existing chimney (PT 2 of 3) (PT 1 of 3)
  • Page 64 English RAIS/ - User manual for VIVA L Gas Vertical Pitched Roof Terminal Distance ”H” = 0-3m (Min - Max) Distance ”V1” = 500mm - 10m (Min - Max) Distance ”V2” = 200mm - 10m (Min - Max) Distance ”V3” = 500mm - 10m (Min - Max) Distance ”V”...
  • Page 65 English RAIS/ - User manual for VIVA L Gas Vertical Roof Terminal with Bend Distance ”H” = 0-3m (Min - Max) Distance ”V1” = 500mm - 10m (Min - Max) Distance ”V2” = 500mm - 10m (Min - Max) Distance ”V”...
  • Page 66 English RAIS/ - User manual for VIVA L Gas Existing chimney (Renovations kit) (PT 3 of 3) F (Flexible flue insert) Ø100 AISA-316Ti) Existing chimney * (PT 2 of 3) (PT 1 of 3) Distance ”V” = 1m - 12m (Min - Max) *Existing chimney/Flue must be inspected by a qualified technician�...
  • Page 67 English RAIS/ - User manual for VIVA L Gas Existing chimney with Bend (Renovations kit) (PT 3 of 3) F (Flexible flue insert Ø100 AISA-316Ti) Existing chim- ney * (PT 2 of 3) (PT 1 of 3) Distance ”H”...
  • Page 68: Chimney Components

    English RAIS/ - User manual for VIVA L Gas Chimney components� US 100 100 (Ø100) US 100 130 (Ø130) Length 1000mm US 25 100 (Ø100) US 25 130 (Ø130) Length 250mm US 50 100 (Ø100) US 50 130 (Ø130) Length 500mm USAB 100 (Ø100)
  • Page 69 English RAIS/ - User manual for VIVA L Gas USDV2 100 (Ø100) Vertical Terminal (+ USKB) USPP 100 (Ø100) USPP 130 (Ø130) Adjustable length USDHCE 10 Horizontal Terminal (Eccentric outlet) USMB 100 (Ø100) USMB 130 (Ø130) Adjustable Wall Strap USEB 100 (Ø100)
  • Page 70 English RAIS/ - User manual for VIVA L Gas USB 90 100 (Ø100) USSR 100 (Ø100) USB 90 130 (Ø130) USSR 130 (Ø130) 90° elbow bend Cover USDPAL 100 (Ø100) USDPAL 130 (Ø130) USB 45 100 (Ø100) Flat roof Cover USB 45 130 (Ø130)
  • Page 71 English RAIS/ - User manual for VIVA L Gas USDH 100 (Ø100) USMPG 100 (Ø100) USDH 130 (Ø130) USMPG 130 (Ø130) Angular Cover Wall Cover 5° - 30° USLS 100 (Ø100) USLS 130 (Ø130) Angular Cover 20° - 45°...
  • Page 72: Declaration Of Conformity

    Viva 100 L Gas Måltegning. D 75 E 400 E 400 D 75 D 75 D 75...
  • Page 73 Viva 120 L Gas Måltegning. D 75 D 75 E 400 E 400 D 75 D 75 D 75 D 75...
  • Page 74 Viva 160 L Gas Måltegning. D 75 D 75 E 400 E 400 D 75 D 75 D 75 D 75...
  • Page 75 Viva 100 L Gas / Viva 120 L Gas / Viva 160 L Gas...
  • Page 76 Viva 100 L G Gas / Viva 120 L G Gas / Viva 160 L G Gas 9-10...
  • Page 77 ATTIKA FEUER AG Brunnmatt 16 CH-6330 Cham Switzerland www�attika�ch RAIS A/S Industrivej 20 DK-9900 Frederikshavn Denmark www�rais�dk...

This manual is also suitable for:

Viva 120 l classic gasViva 160 l classic gas

Table of Contents