Life Ionizers Next Generation LIFE MXL-5 C User Manual page 21

Table of Contents

Advertisement

AMPERAGE ADJUSTMENT (F20)
(help video on LifeIonizers.com/support)
To enter into the F20 you will need to do the following:
NOTE:
The buttons must be pressed quickly as failure to do so will
result in booting you out of the program menu. The unit must be
dispensing water before pressing the buttons.
Turn on ionizer and scroll through the alkaline and acid levels by
pressing the
"ALKALINE"
adjust.
Press and hold the
for 5 to 10 seconds (or until F20 appears on screen).
F20 will appear on the display screen.
Below the F20, the amperage number will display.
To increase the amperage number, press and release the
button. The number will go up automatically. Release to stop.
To decrease the amperage number, press and release the
"FILTER 1"
button. The number will go down automatically.
Release to stop.
Test the level of alkaline by adding 3-4 drops of the pH solution
we recommend to 1 ounce of water. Set levels below to:
ALK 1 - light blue
ALK 2 - blue/purple
ALK 3 - purple
ALK 4 - dark purple
If the color is not matching the pH chart, you may need to raise
or lower the amperage until the desired color is correct.
To save your adjustments, press the
display screen will go back to its normal operation.
NOTE: You cannot adjust the
Repeat the process to adjust the other levels of alkaline or acid.
For optimum performance of the unit, you will need to clean
your ionizer with the CITRIC ACID CLEANING FILTER also known
as the SCALING FILTER. We recommend using this cleaning
cartridge 3-4 times a year depending on the hardness of your
water.
LifeIonizers.com/support
or
"ACID"
button. Select the level you want to
"MENU"
&
"FILTER 1"
"PURIFY"
21
buttons simultaneously
"PURIFY"
button and the
selection.
"FILTER 2"
LIFE MXL-5

Advertisement

Table of Contents
loading

Table of Contents