Page 1
LS zone 2 Accommodations PABX LS zone 3 Lifeboat area Telephone LS zone 4 Engine area LS zone 5 Open deck Entertainment LS zone 6 Open deck System Manual PUBLIC ADDRESS & GENERAL ALARM SYSTEM SPA-V2 TECHNICAL MANUAL A100K10369 v.4.0...
2.3.3 Zones ................... 8 2.3.4 CTB Panel Input ................9 2.3.5 Panels for Alternative Priorities in SPA-V2 ........9 3 System Overview & Types .............10 System Type Name ..............10 Standard Basic PA Functions ..........11 3.2.1 PA Microphone Panel Functions ..........11 3.2.2...
Page 3
5.3.10 HP-30T ..................46 5.3.11 DST-100 ..................46 5.3.12 DH-30 ..................46 5.3.13 DH-50 ..................46 5.3.14 BF-560STT ................. 47 5.3.15 VES-561TF ................. 47 5.3.16 CAREEX-6T ................47 5.3.17 DSP-15EEXMNT ................ 47 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Page 4
Figure 43 Boards & Connectors for Alarm panel SPA-W1AR-D ................36 Figure 44 Boards & Connectors for Alarm panel SPA-W6A4 ................... 38 Figure 45 Boards & Connectors for Alarm panel SPA-W6A4-D ................39 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Outline drawings in AutoCAD Amplifier and Entertainment manuals 1.4 Rules and Regulations The SPA-V2 Public Address and General Alarm System is designed to meet the requirements in accordance with SOLAS: - Chapter III, part B, regulation 6.4 and 6.5 - MSC.48(66) – International Life-Saving Appliance (LSA) Code - MSC/Circ.808 –...
● Alarm mute relay during PA message TEST DISCONNECTION VOLUME ● Predefined for up to 8 alarm panels (2 included & 6 optional) and SIGN TALK MENU NEXT ALARM ALARMS ALARM ServoMaster Fire alarm Talk-back alarm module ● Input for alarm start from fire exchange (with alarm generator installed) with distribution to specified zone Figure 1 Typical basic PA configuration A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
● External alarm warning equipment can be connected to SPA Alarm Relay Boards which have three potential free relay contacts (SPA- BASIC TERMINAL BOARD B AL-REL-V2) RELAY ALARM GEN. 900-024 BOARD Figure 4 Basic requirements, conventional vessels (DNV) A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
- Alarm and microphone panels can be set to one, two or more of the six zones or all zones. - Entertainment distribution can be restricted to pre-selected zones. - Only fire crew can have zone set in default version of system. A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
The CTB panel is optional. There is input in the system which makes the CTB panel connection to have the highest priority. When the system is used as PAGA, this input shall not be regarded as part of the system. 2.3.5 Panels for Alternative Priorities in SPA-V2 Optional 1 priority...
● For muting of external alarm sound equipment when PA message is broadcasted or for muting of loudspeaker which may cause feedback to PA microphone. - Integrated relay on terminal board (X5) BASIC TERMINAL BOARD Figure 8 Alarm Mute function A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
(part of SPA-xxx-V2) SINGLE 4-WIRE ENT. BOARD ● Entertainment can be turned on/off by a switch in front of rack. ENT. on/off ● Jumper for selection of emergency or normal volume override Figure 11 Entertainment, single amplifier, 4-wire override A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
● Output for external alarm warning equipment through Relay Board AL-REL6-V2 with three potential free relay contacts: - General alarm, steady - General alarm, pulsing - General alarm, pulsing with mute - Manual steady - Abandon steady A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
3.3.9 Power Failure Control 2 ● Amplifiers operate normally from 230 VAC power supply ● Amplifiers can operate from 230 VAC emergency, supplied from an uninterruptible power supply (UPS) if 230 V mains fail. ● SPA-UPS comes with power failure outputs Figure 18 Power fail-over to 230 VAC A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
990-552 SPA-TERMINALBOARD V2 - RJ45 contacts for interface to function boards - separate volume controls for all audio inputs - zone and priority configuration jumpers A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
> F AUDIO > F AUDIO ACTIVE > F AUDIO > -24V > +24V Figure 22 Terminal board connectors Doc no. A100K 10369 System Manual Page 17 SPA-V2 PA/GA Systems A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
The jumpers are normally set according to project specifications at delivery, but may be changed if modifications are needed after installation. Note that some function boards have jumpers that need to be set. See the SPA-V2 Configuration & Installation manual for jumper settings. ENTERTAINMENT OUT ZONE SELECTION ALARM PRIORITY EXTERN AMPLIFIER OVERRIDE...
>+24 V >+24 V >+24 V >+24 V >-24 V >-24 V >-24 V >-24 V >+24 V >+24 V >-24 V >-24 V Figure 29 SPA-ENT4-v2 board & connectors A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
EMS+ALL - EMS ONLY > SW ITCH OUT > SWITCH OUT > SWITCH OUT Doc no. A100K 10369 System Manual Page 23 Figure 31 SPA-EMS v2 board & connectors SPA-V2 PA/GA Systems A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
> SWITCH OUT > SWITCH OUT X100 X100 Page 24 System Manual Doc no. A100K 10369 Page 24 System Manual Doc no. A100K 10369 SPA-V2 PA/GA Systems SPA-V2 PA/GA Systems A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
18 - Remote volume control 19 - Priority over entertainment input Doc no. A100K 10369 System Manual Page 25 Doc no. A100K 10369 System Manual Page 25 SPA-V2 PA/GA Systems SPA-V2 PA/GA Systems A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
IEC 168-3 Electrical measures Safety according to CEI 65 Indicator Front VO meter, power and failure, overload lamp 19” rack mounting Mounting Table 1 Technical specifications for VPA amplifiers A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
● General Alarm pulsing with PA mute GA OUTPUT MUTE BY GA OUTPUT PULSING GA OUTPUT STEADY PULSING PULSING COMMON COMMON COMMON MUTE STEADY +24V X163 X162 X161 GA-ON ABANDON ON MANUAL ON X160 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
● Over-load and short-circuit protected ● DNV-GL approved 4.5.8 PROMAX-240-24 Power supply 100-240VAC/24VDC 10A ● DIN Mounted additional power supply for rack equipment ● Over-load and short-circuit protected ● DNV-GL approved A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Field Equipment For Mounting & Installation instructions, see SPA-V2 Configuration and Installation manual. 5.1 PA & Alarm Panels 5.1.1 SPA-M1-V2 SPA-M1 Single PA panel, all call for indoor use. ● For gooseneck mic. ETC-1-TB or handheld microphone MB-30G ● Built-in pre-amplifier with preset signal level and separate BASS &...
< ZONE 4 < ZONE 5 < ZONE 6 < EMS > + 24VDC EMS INPUT > 0 V LOCAL MUTE Figure 36 Board & Connectors for PA panels SPA-M1-D A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
< ZONE 6 < EMS EMS INPUT PWM INPUT SPA-M1 & SPA-M6 > + 24VDC > 0 V LOCAL MUTE Figure 37 Board & Connectors for PA panels SPA-M6-V2 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
< ZONE 4 < ZONE 5 < ZONE 6 < EMS > + 24VDC EMS INPUT > 0 V LOCAL MUTE Figure 38 Board & Connectors for PA panels SPA-M6-D A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
START GENERAL > LAMP GENERAL > LAMP ABANDON > LAMP MANUAL EMS INPUT PWM DIMMER IN < FIRE ALL < FIRE CREW Figure 39 Board and Connectors for SPA-AC6 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Wall with 4x4 mm screws Dimensions: 140W x 230H x 125D mm Cabling: Pluggable screw terminals, max 2.5 mm2 cable Cable glands: 2 x PG-16 Weight: 0.5 Kg Protection: IP66 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Wall with 4x4 mm screws Dimensions: 140W x 230H x 125D mm Mic Connector Cabling: Pluggable screw terminals, max 2.5 mm2 cable Cable glands: 4 x PG-16 Weight: 0.5 Kg Protection: IP66 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Wall with 4x4 mm screws Dimensions: 140W x 230H x 125D mm Cabling: Pluggable screw terminals, max 2.5 mm2 cable Cable glands: 2 x PG-16 Weight: 0.5 kg Protection: IP66 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
140W x 230H x 125D mm Cabling: Pluggable screw terminals, max 2.5 mm2 cable Cable glands: 2 x PG-16 Weight: 0.7 Kg Protection: IP66 Figure 43 Boards & Connectors for Alarm panel SPA-W1AR-D A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Wall with 4x4 mm screws Dimensions: 140W x 230H x 125D mm Cabling: Pluggable screw terminals, max 2.5 mm cable Cable glands: 2 x PG-16 Weight: 0.7 Kg Protection: IP66 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Wall with 4x4 mm screws Dimensions: 140W x 230H x 125D mm Cabling: Pluggable screw terminals, max 2.5 mm cable Cable glands: 2 x PG-16 Weight: 0.7 Kg Protection: IP66 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
> 0 V < RESET < START MANUAL < START ABANDON < START GENERAL > LAMP GENERAL > LAMP ABANDON > LAMP MANUAL EMS OUT < FIRE ALL < FIRE CREW A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Doc no. A100K 10369 System Manual Page 43 Plug 5-pole DIN SPA-V2 PA/GA Systems Doc no. A100K 10369 System Manual Page 43 Supply 1.1 - 9V SPA-V2 PA/GA Systems Accessories Sponge windscreen A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Pluggable screw terminals max 2.5 mm cable <+24 V OVER RID E Cable glands 1 x PG-29 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System < -2 4V O VER RI DE Weight Approx. 0,7 Kg System Manual <10 0 V LINE IN...
< -24V O VER RIDE <10 0V LINE IN <10 0V LINE IN > 10 0V LINE O UT >10 0V LINE O UT Figure 80 Drawing & wiring of volume control VM15-RD A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
< -24V O VER RIDE <10 0V LINE IN <10 0V LINE IN > 10 0V LINE O UT >10 0V LINE O UT Figure 80 Drawing & wiring of volume control VM15-RD A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
200Ø x 247D mm Weight: 1.7 Kg Protection: IP56 5.3.3 CL-200T Loudspeaker, fl ush-mounted with steel fi re dome and backbox, 10W Technical data Mounting: Ceiling Dimensions: 199Ø x 121.5D mm Weight: 1.45 Kg Protection: IP44 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Horn loudspeaker 15W 100V transformer with fuse for use in deck areas, engine room, etc. Technical data Dimensions: 253W x 152H x 309D mm Weight: 1.85 Kg Protection: IP66 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Weight: 3.6 Kg Protection: IP67 5.3.13 DH-50 Horn for driver DST-100, WT for use in deck areas. Technical data Dimensions: 508Ø x 505D mm Weight: 5.15 Kg Protection: IP67 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
186W x 144H x 207D mm Weight: 2.2 Kg Protection: IP-67 5.3.18 DHP/DST-40EEXENT Antistatic Horn W/ Atex App. 40W Driver Technical data Dimensions: 368W x 175H x 380D mm Weight: 4.0 Kg Protection: IP-67 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Page 48
220Ø x 172D mm Weight: 3,0 Kg Protection: IP-67 5.3.20 HP-20EEXIINT Loudspeaker 20W, 100V, Ex Zone 2 Technical data Dimensions: 237Ø x 286D mm Weight: 2,3 Kg Protection: IP-67 A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Page 49
A100K10369 v4.0 SPA-V2 Public Address & General Alarm System System Manual...
Page 50
www.zenitel.com Zenitel Norway AS The WEEE Directive does not legislate that Zenitel, as a ‘producer’, shall collect ‘end of life’ WEEE. This ‘end of life’ WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measures. It should not be disposed to landfi ll. Many electrical items that we throw away can be repaired or recycled.