Balluff BIS M-87 User Manual
Balluff BIS M-87 User Manual

Balluff BIS M-87 User Manual

Handheld programmer
Hide thumbs Also See for BIS M-87:

Advertisement

Quick Links

Handheld Programmer BIS M-87_
Technical Description, User's Guide
english

Advertisement

Table of Contents
loading

Summary of Contents for Balluff BIS M-87

  • Page 1 Handheld Programmer BIS M-87_ Technical Description, User's Guide english...
  • Page 2 www.balluff.com...
  • Page 3: Table Of Contents

    Operation 5.1 Keyboard, display and operating concept 5.2 Reading data carriers 5.3 Writing to data carriers 5.4 Editing data 5.5 Initializing data carriers 5.6 Working with files 5.7 Connecting the Handheld Programmer to a PC/laptop Technical Data Appendix Index www.balluff.com...
  • Page 4: User Instructions

    Installation and operation of accessories and expansion devices, – Docking station and device interfaces. The newest information for the product can be found on the internet at “www.balluff.de”. 1.4 Structure of the The manual is organized so that the sections build on each other.
  • Page 5: Symbols

    Keys are set in angle brackets, e.g. confirm by pressing <Enter>. 1.6 Symbols Caution! This symbol indicates a security notice which must be observed. Note, tip This symbol indicates general notes. Balluff Identification System 1.7 Abbreviations Cyclic Redundancy Check EEPROM Electrically Erasable Programmable Read Only Memory Electromagnetic Compatibility...
  • Page 6: Safety

    You can also return the included batteries to the following address (with sufficient postage) after using them: Balluff GmbH, Schurwaldstraße 9, 73765 Neuhausen a.d.F., Germany Caution! Use only Balluff-approved power supplies.
  • Page 7: Getting Started

    The system components of the Handheld Programmer are powered by a 3.7 V rechargeable battery pack (Li-Ion). ► Please charge rechargeable batteries provided by Balluff before using them for the first time! Fig. 3: Connecting the power supply – Charging the battery pack Changing A high-capacity rechargeable battery has a battery life of up to 48 hours after a full charge.
  • Page 8: Overview Of Workabout Pro C

    Handheld Programmer BIS M-87_ Getting Started 3.2 Overview of WORKABOUT PRO C BIS M-870-1- 0_ _-X-001 Fig. 4: Handheld Programmer BIS M-870-1-0_ _-X-001 Ø ≥ 20 mm Read/write head for BIS U data carrier with round coil Active surface (underside) BIS M-871-1- 0_ _-X-001 Fig.
  • Page 9 BIS M-870-1- 0_ _-X-004 / BIS M-870-1- 0_ _-X-005 Fig. 7: Handheld Programmer BIS M-870-1-0_ _X-004 / BIS M-870-1-0_ _-X-005 Ø ≥ 20 mm Read/write head for BIS M data carrier with round coil Barcode scanner Active surface (underside) www.balluff.com...
  • Page 10 Handheld Programmer BIS M-87_ Getting Started BIS M-871-1- 0_ _-X-004 / BIS M-871-1- 0_ _-X-005 Fig. 8 : Handheld Programmer BIS M-871-1-0_ _-X-004 / BIS M-871-1-0_ _-X-005 Read/write head for BIS M-15_-XX data carrier Barcode scanner Active surface (underside) BIS M-873-1- 0_ _-X-004 / BIS M-873-1- 0_ _-X-005...
  • Page 11: Cold Reset Or Battery Replacement

    The user's guide is available on the internet at: www.zebra.com/workaboutpro4 concept 3.6 Creating your Note own operating The BALLUFF.dll has been created as a discrete software solution for creating a interface custom user interface. The order number for this software is available on request. www.balluff.com...
  • Page 12: Starting The Rfid Application

    Getting Started ► On the Windows CE desktop, tap on 3.7 Starting the RFID application “Start > Programs > BALLUFF RFID > BIS M RFID” (depending on the Windows CE version, instead of “Start” tap on the 4-color Windows logo.
  • Page 13 Processes all Balluff-supported data carrier types (default setting). Mifare All Balluff supported Mifare data carriers are processed. ISO15693 All Balluff supported ISO 15693 data carriers are processed. Note BIS M-87_-1-008-00_ : All, Mifare & ISO15693 data carriers BIS M-87_-1-010-00_ : ISO15693 data carriers Use CRC Check Uses the CRC checksum.
  • Page 14 Handheld Programmer BIS M-87_ Getting Started Hardware types BIS M-870-… : Portable reader with integrated read/write head for BIS M- data carriers with round coil Ø ≥ 20 mm BIS M-871-… : Portable reader with integrated read/write head for BIS M- data carriers with rod type antenna (BIS M-15_ ...) BIS M-873-…...
  • Page 15 ⇒ The data can be chan- ged using the keyboard. ► Confirm the change with [OK]. ⇒ The entry field is closed, the changed data are displayed on the “RW Data” tab. Fig. 16: Example - Editing data www.balluff.com...
  • Page 16 Handheld Programmer BIS M-87_ Getting Started “File Browser” “File Browser” can be used to load or save files. Fig. 17: “File Browser” tab [Open] Opens the “Open file…” dialog. A saved file can be selected and opened. The data are displayed on the “RW Data” tab. [Save] Opens the “Save file as…”...
  • Page 17 Handheld Programmer BIS M-87_ Getting Started “About” tab Display of the software version and manufacturer information. Fig. 18: “About” tab www.balluff.com...
  • Page 18: Basic Knowledge

    Saving/loading files. Creating your Note own operating The BALLUFF.dll has been created as a discrete software solution for creating a interface custom user interface. The order number for this software is available on request. 4.3 Control function The Handheld Programmer is the link between data carrier and controlling system. The Handheld Programmer can be used to check, correct or initialize data carriers.
  • Page 19: Files

    No. of bytes Data carrier data data carrier 4 bytes 4 bytes Max. 184 bytes Example: Data carrier file starting at Address 75 with 16 bytes of data in ASCII format. Data: ABCDEFGHIJKLMNOP Contents of data carrier file: 00750016ABCDEFGHIJKLMNOP www.balluff.com...
  • Page 20: Data Carrier Types

    Handheld Programmer BIS M-87_ Basic Knowledge 4.6 Data carrier The following data carrier types are compatible with the BIS M-87 Handheld Programmer. types Depending on the selection all or only a particular data carrier (Mifare or ISO 15653) can be processed.
  • Page 21: Crc Check

    The checksum is written to the data carrier as 2 bytes of information. 2 bytes per block are lost. This leaves 14 bytes per block available. The usable number of bytes can be found in the follow- ing table. Balluff data carrier type Memory capacity Usable bytes for CRC_16...
  • Page 22: Operation

    The user's guide is available on the internet at: www.zebra.com/workaboutpro4 concept 5.2 Reading data carriers ► Start Balluff RFID Reader. ► Make desired settings. ► Activate read/write head by tapping [Open reader]. ⇒ The settings are grayed out and the button changes to [Close reader].
  • Page 23: Writing To Data Carriers

    Read error Fig. 21: Write operation successful Fig. 22: 5.3 Writing to data carriers ► Start Balluff RFID Reader. ► Make desired settings. ► Activate read/write head by tapping [Open reader]. ⇒ The settings are grayed out and the button changes to [Close reader].
  • Page 24 BIS M-87_ Operation ► Switch to the “RW Data” tab Writing to data carriers, cont. ► Start Balluff RFID Reader. ► Make desired settings. ► Activate read/write head by tapping [Open reader]. ⇒ The settings are grayed out and the button changes to [Close reader].
  • Page 25: Editing Data

    ► Edit data using the keyboard and confirm with [OK]. ⇒ The editor is closed and the changed data are displayed. Fig. 27: Editing data carriers The data carrier is programmed with 00 and thereby prepared for operation with a CRC data check. www.balluff.com...
  • Page 26: Initializing Data Carriers

    BIS M-87_ Operation ► Switch to the “Settings” tab 5.5 Initializing data carriers ► Start Balluff RFID Reader. ► Activate“Use CRC Check” . ► Activate read/write head by tapping [Open reader]. ⇒ The settings are grayed out and the button changes to [Close reader].
  • Page 27: Working With Files

    (see also “Cold Reset”, Section 3.3 on page 10). The safest place to store the data is an SD or MMC memory card (flash disk). www.balluff.com...
  • Page 28: Connecting The Handheld Programmer To A Pc/Laptop

    Handheld Programmer BIS M-87_ Operation ► Switch to the “File Browser” tab. Loading files ► Tap on [Open]. ⇒ The “Open” dialog opens. ► Select file and confirm with [OK]. ⇒ The saved data are read and displayed on the “RW Data” tab.
  • Page 29: Technical Data

    Handheld Programmer BIS M-87_ Technical Data Dimensions Fig. 32: Dimensions BIS M-870-1-0_ _-X-001 (in mm) Fig. 33: Dimensions BIS M-871-1-0_ _-X-001 (in mm) Ø 14,5 Fig. 34: Dimensions BIS M-873-1-0_ _-X-001 (in mm) www.balluff.com...
  • Page 30 Handheld Programmer BIS M-87_ Technical Data Fig. 35: Handheld Programmer BIS M-870-1- 0_ _-X-004 / BIS M-870-1- 0_ _-X-005 (in mm) Fig. 36: Dimensions BIS M-871-1- 0_ _-X-004 / BIS M-871-1- 0_ _-X-005 (in mm) Fig. 37: Dimensions BIS M-873-1- 0_ _-X-004 / BIS M-873-1- 0_ _-X-005 (in mm)
  • Page 31 4000 mAh Max. charging voltage Charging current 0.9 A Charging time Battery life Operating Ambient temperature -10 °C…+50 °C conditions – EN 61000-4-2/3/4/5/6 – Severity level 3A/3A/–/–/– – EN 55011 – Size 1, Cl. A Vibration/shock EN 60068 Part 2-6/27/29/64/32 www.balluff.com...
  • Page 32: Appendix

    Ø ≤ 19 mm Interface 1 = Bluetooth Software type 008 = Standard Balluff Software for BIS _-87x-... 010 = Fast Read/Write Balluff Software for BIS _-87x-... Language X = Multilingual Additional features 001 = WLAN...
  • Page 33 Primary voltage U 100-240 V primary Secondary voltage U ± 5 % Input frequency F 50-60 Hz primary Secondary current I 800 mA Ambient temperature T −40 °C ... +70 °C Material PPE-V1-125 °C Color black Material number 11023834 Color black www.balluff.com...
  • Page 34 Handheld Programmer BIS M-87_ Appendix ASCII table Decimal Control ASCII Decimal ASCII Decimal ASCII Code Ctrl @ Ctrl A Ctrl B Ctrl C Ctrl D Ctrl E Ctrl F Ctrl G Ctrl H Ctrl I Ctrl J Ctrl K Ctrl L Ctrl M Ctrl N Ctrl O...
  • Page 35: Index

    Main components 18 Meaning Data carrier Warning notes 6 Initalizing 21 Improper 6 Types 20 Intended 6 Operating conditions 31 Data integrity 18 Data transmission 28 Dimensions 29 Parameters Docking station 33 CRC_16 data check 13 Product description 18 www.balluff.com...
  • Page 36 Balluff GmbH Schurwaldstraße 9 73765 Neuhausen a.d.F. Germany Tel. +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de www.balluff.com...

Table of Contents