Page 3
WELCOME Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information. EMAIL LOCATION support@acinfinity.com www.acinfinity.com...
RACK COOLING GUIDE ACCESS TO OUTSIDE AIRFLOW For the fan system to work properly, the rack fan must have access to outside air. It can be ventilation holes on the rack or on the cabinet if it’s holding an open frame rack.
KEY FEATURES ALUMINIUM FRAME QUIET PWM MOTOR SMART CONTROLLER Features an aluminium frame PWM-controlled motor features LCD display enables temp with a brushed black finish precise speed control, reduced monitoring, thermal control, and CNC machined corners rotor noise, and runs on energy speed control, alarms, and give cabinets a clean look.
INSTALLATION STEP 1 Determine the position you wish to mount the rack fan unit onto your rack. Please refer to page 6 for a guide on the best fan placement to optimize cooling. STEP 2 Use a screwdriver and the included screws to secure the fan unit onto your rack.
Page 10
INSTALLATION STEP 3 Check the included AC power adapter to make sure the power rating is compatible with your outlet. Plug the DC connector of the AC power adapter into the port labeled “POWER” on the backside of the rack fan unit. STEP 4 Plug the AC power adapter into a standard power outlet.
Page 11
INSTALLATION STEP 5 Plug the male connector of the thermal probe into the port labeled “PROBE” on the backside of the rack fan unit. Please check that the LCD screen now displays the probe’s temperature readings. STEP 6 Secure the head of the probe onto the rack using the included cable ties.
Page 13
PROGRAMMING 1. MODE BUTTON 2. LEAF BUTTON 3. UP / DOWN BUTTON Cycles through the modes: This turns the display off The up and down buttons AUTO, SMART, SPEED, while programs run in the adjusts the settings of the ALARM, BUFFER. Holding background.
Page 14
PROGRAMMING QUICK START Press the MODE button until you are on AUTO mode. This mode works like a thermostat. Press the up and down triangle buttons to change the SETTING temperature on the screen. The PROBE temperature is what the thermal probe is measuring. When the PROBE temperature exceeds the SETTING temperature, the fans will start running.
Page 15
PROGRAMMING BUFFER SETTING SETTING SPEED In AUTO mode, a buffer is built in to prevent PROBE your fan from turning on and off too quickly due to small variations in the environment. ALARM BUFFER In SMART mode, there is a range of temperatures between each speed.
Page 16
PROGRAMMING ALARM SETTING In this mode, you can set what temperature SETTING SPEED the system’s alarm will trigger by pressing PROBE the up and down triangle buttons. When the PROBE temperature reaches or exceeds ALARM BUFFER the ALARM temperature, the alarm will activate.
Page 17
PROGRAMMING FAHRENHEIT OR CELSIUS The temperatures displayed can be set to Fahrenheit or Celsius scale by holding the LEAF button until °F or °C is shown after the digits. All digits displayed will be automatically converted to the designated scale. DISPLAY BRIGHTNESS To adjust the brightness of the display, hold down the MODE button while pressing the up button repeatedly to increase the brightness.
Page 18
PROGRAMMING ALERT ICONS On the bottom right of the display there are three alert icons. They are visible to show that the system’s functions are being monitored. They will flash when the controller wishes to alert you that a particular function is being triggered. SETTING SPEED PROBE...
Page 19
EXTENSION FAN UNITS CLOUDPLATE SERIES To add more cooling and ventilation to your rack, you can plug in additional fans such as the RACK ROOF FAN into a CLOUDPLATE Series unit. There is a port on the backside marked “EXT.” which allows the unit to support additional fans. You can also connect one CLOUDPLATE unit to another to share the same settings;...
Page 20
AC INFINITY PRODUCTS AIRCOM SERIES The AIRCOM component fan system cools receivers, amplifiers, and other AV components. S-Series models features a thermal trigger and speed control. T-Series features a LCD digital display with thermal and speed control, alarm alerts, failure triggers, and backup memory. DIMENSIONS MODEL 11.6 x 6.3 x 1.5 in.
WARRANTY This warranty program is our commitment to you, the original purchaser, that each product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues.