LED Error Messages
Before cooling, the LED will blink three (3) times in two (2) second intervals. The LED message is
defined by the blinking sequence. A long blink is defined as 1 second. A short blink is defined as
0.3 seconds. The LED messages are listed below:
e
rrOr cOde MeSSaGe
Environment Over Temperature
DMD Over Temperature
Lamp Over Temperature
Fan1 Locked
Fan2 Locked
Fan3 Locked
Fan4 Locked
DMD Initial Fail
Lamp Initial Fail
Ballast UART Error
Temperature Sensor Fail
Inter Lock Open
led f
laSh
1 long blink / 1 short blink
1 long blink / 2 short blinks
1 long blink / 3 short blinks
1 long blink / 4 short blinks
2 long blinks / 2 short blinks
2 long blinks / 3 short blinks
2 long blinks / 4 short blinks
3 long blinks / 1 short blink
3 long blinks / 2 short blinks
3 long blinks / 3 short blinks
3 long blinks / 4 short blinks
4 long blinks / 1 short blink