6.19. Remove the K-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the coupler (H53). (see section 6.5.)
3. Remove the screws (×3
6.20. Remove the stand brackets
1. Remove the plasma panel section from the servicing stand
and lay on a fiat surface such as a table (covered) with the
plasma panel surface facing downward.
2. Remove the stand brackets (left, right) fastening screws (×6
each) and remove the stand brackets (left, right).
) and remove the K-Board.
6.21. Remove the Plasma panel
section from the Front frame
(glass)
1. Remove the front frame and the plasma panel fastening
screws (×8
).
2. Remove the front frame and the stand brackets fastening
screws (×6
).
3. For leaving the plasma panel from the front frame, pull the
bottom of the front frame forward, lift, and remove.