2.4.2 USE: START-UP AND SWITCH OFF

2.4.2.1 Start-up the UPS, mains available
To switch on the UPS press and hold the "ON/Mute" button (1) for at least 2 seconds. On the display the symbols "AC
NORMAL" (7) and "CHARGING" (8) are lit. NOTE: When you turn on the UPS it will perform a self-test.
2.4.2.2 Start-up the UPS, mains not available
If you switch on the UPS if mains power is not available, the UPS is started up in battery mode: it discharges the batteries.
The symbol "BATT MODE" (9) lights and an alarm sounds. To mute this alarm press and hold the "ON/Mute" button for at
least 4 seconds to toggle between alarm on/off. This switch does not mute the alarm in case of low battery voltage or
abnormal operating conditions.
2.4.2.3 Switch off the UPS
Press and hold the OFF/Enter button (3) for at least 2 seconds. If the UPS operates in AC mode it will switch to standby, if
the unit operates in battery mode it will switch off.

2.4.3 USE: OPERATING MODES

2.4.3.1.Standby Mode
Mains supply is connected, battery is charging but UPS is not switched on yet. On the display the symbols "AC NORMAL"
(7) and "CHARGING" (8) are lit.
2.4.3.2 AC Mode (normal operation)
On the display the symbols "AC NORMAL" (7) and "CHARGING" (8) are lit.
The mains voltage is present, the UPS supplies the connected equipment and keeps the battery in a fully charged state.
The load is isolated from surges and electrical noise brought by the mains wiring.
2.4.3.3 DC Mode (Battery Mode)
On the display the symbol "BATT. MODE" (9) is lit. The mains power fails and the UPS uses the energy stored in the batteries
until either they are depleted or mains power returns. The "Battery capacity" bar (5) shows the remaining battery capacity
and the buzzer sounds. To mute this alarm press and hold the "ON/Mute" button for at least 4 seconds to toggle between
alarm on/off.
modifications reserved
GE_UPS_OPM_VCO_XXX_1K0_3K0_XGB_V017
GE
Standby mode: UPS switched off, input voltage present, battery charging
AC mode – normal operation
DC (battery) mode - battery capacity >= 40%
AC mode – output overload (102-129%), after 15 secs transfer to bypass
DC mode – output overload (102-129%) after 15 secs shutdown
DC mode – battery capacity <= 20%
AC mode – output overload (130-149%), after 2 secs transfer to bypass
DC mode – output overload (130-149%), after 2 secs shutdown
AC mode – output overload (>150%), immediate transfer to bypass
DC mode – output overload (>150%), immediate shutdown
abnormal operating condition:
output short circuit; Inverter over/under voltage; Over temperature; Charger
over voltage; Charger fault; Bus over/under voltage
UPS operating status
User manual - VCO Series UPS 1000-3000VA V017 - GB