Technical summary
The battery system is a self-contained regulated power supply, battery, and charger unit,
packaged in a sheet metal enclosure.
Features
• Universal AC input
• Regulated 12V DC output
• Fast charging
Electrical specifications
Input
Input voltage
Input frequency
Inrush current limiting
Input protection
Power factor
Output
Output voltage
Output current
Output power
Overload recovery
Overload protection
Operating time
Output efficiency
Invitium Battery System BAT-24CM
• Intelligent communications (USB host)
• Cooling fan
• Externally accessible fuses
85 to 265 VAC
47 to 63 Hz
<50A peak
2A, 250V replaceable fuse
0.95 (150 W, 230 VAC)
12 VDC ±5%
6.0 A maximum
36 watts nominal; 72 watts maximum
Automatic upon fault removal
6A replaceable fuse
4 hours at nominal output power
>88%