Troubleshooting
Problem
The battery system not functioning,
no output power, does not charge
when connected to AC power.
No power supplied to Invitium system.
System run time is too short.
Invitium Battery System BAT-24CM
Possible Cause
AC power is not connected.
Input fuse needs to be replaced.
Over-temperature protection is activated.
Output power cord not connected properly.
Power switch is off.
Output fuse needs to be replaced.
Batteries not connected correctly.
Battery not completely charged.
Battery capacity is low.
Possible Solution
Make sure power cord is connected properly
Replace fuse in input connector. Replace
with UL recognized fuse 2 A, 250 VAC,
fast acting, size 5 mm x 20 mm.
Contact Planar.
Make sure that output power cord is
connected correctly. When the power LED
on the right side of the Invitium workstation
is green, it indicates normal operating mode.
Turn on the power switch, located on
the right side of the Invitium workstation.
Replace the output power fuse located next
to output power connector. Replace with
UL recognized fuse 6 A, 125 VDC, fast acting,
size.25 in. x 1.25 in.
Check battery connections.
Connect AC power and let battery charge
completely. Charge status is conveyed
through the
Power Meter tab
on the
Power Options Properties dialog box.
Replace battery.