Configuration and installation processor guide
INDEX
Functional Diagram..............................
Step by step configuration..................
Installation............................................
!
Caution:
- The installation may be done in covered local,
ventilated and no vibration. Install the device in
adequate local.
- Please, protect the LCD out of direct solar
radiation, covered and ventilated.
- The recommendations above guarantee the correct
function of the system.
Technical Especifications
Frequency response.....................
20 Hz - 20 KHz (com filtro ativo)
Equalização (Frequencies)...........
(31,40,50,63,80,100,125,160,200,250,315,
400,500,630,800,1000,1250,1600,2000,2500,
3150,4000,5000,6300,8000,10000,12500,16000)
Equalização (Gain).......................
-12dB / +12dB
HIPASS Filter................................
20 Hz - 20 KHz
LOWPASS Filter...........................
20 HZ - 20 KHz
Attenuation Filter............................
6 / 12 / 18 / 24 / 36 / 48 (dB/8º) / OFF
MUTE............................................
-100 dB
Gain..............................................
-18dB / 6dB
Phase...........................................
0º / 180º
Delay.............................................
399 Samples - 286,7cm
Input Sensitivy..............................
0,1 - 4 Vpp
Output Signal. ...............................
0 - 8 Vpp
Input impedance...........................
47 KOhm
Output impedance.........................
100 Ohm
ADC SNR......................................
100 dB
DAC SNR......................................
104 dB
THD + N........................................
0.02%
Resolution.....................................
24 Bit
Frequency Sample........................
48 KHz
Dimensions....................................
120 x 250 x 30mm
Weight...........................................
0,42 Kg - 0,92 Lb
1
1
02
03-05
06
Configuration and installation processor guide
8. PHASE:
Press the ESC button to go initial display.
Turn the Encoder until the Phase function
1º Step: PHASE
2º Step: 0º ou 180º
PHASE
CH1>PHASE: 0
Turn the Encoder:
Press the channel to
configure:
Choose the phase 0 or
180. Press ESC button
to return.
9. DELAY:
Press the ESC to go initial display.
Turn the ESC button to go initial display.
1º Step: Delay
2º Step: Distance
CH1>DELAY: 1 sample
DELAY
0007 mm
Turn the Encoder:
Press the channel to
configure:
Choose the distance.
Press ESC to return.
Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 ESC
PX- 2
Ch6
Ch5
Ch4
Ch3
Amplifier's CHannels
EXPERT
FUNC
ELECTRONICS
6 CH
46 - EQ
LIMITER
OUT
Ch2
Ch1
IN L
IN R
L
R
PLAYER
LINK
Negative/Ground
Remote from player
connect to remote
input the processor
Remote output
connect to amplifiers
Positive/Supply
(10~15v)