OVERVIEW The AV102SS intercom system designed to interface directly with the Adpro fast-scan, FastVu and FastTrace Video/Audio transmission systems. It is constructed entirely of Stainless Steel for the ultimate in durability and robustness. It is Vandal-Resistant and weatherproof, making it ideal for use in external public areas such as help-points, door and gate access control systems and lift intercoms.
Do not connect any power until installation has been completed and checked. DO NOT use the CW1308 audio cable to run the DC power to the call-point : Run a separate 2-core cable (See notes below regarding cabling). DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 3 of 22...
The CALL OUT signal (from the AVPSU4 to the transceiver alarm input) may be any type of two-core cable. Please refer to the drawing on the next page as a guide to cable connections. DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 4 of 22...
Page 6
“Switcher” (15 Pin “D” type connector) LSP+ LSP- MIC+ MIC- LSP+ LSP- MIC+ MIC- SPARE VIDEO GROUND +12V VIDEO GROUND-LOOP ISOLATION TRANSFORMER VIDEO OUTPUT WHITE/GREEN PAIR C GREEN/WHITE DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 5 of 22...
Page 7
DETAILS OF CALL-POINT CONNECTIONS : CALL-POINT WITH LOCAL HANDSET The AV102SS may be used as a stand-alone intercom using the AVSHS01 handset. This application may only be used with a single intercom call-point or a single master/slave combination. DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1...
Page 8
DETAILS OF CALL-POINT CONNECTIONS : CALL-POINT CONNECTED TO ADPRO REMOTE TRANSMITTER WITH LOCAL HANDSET FOR LOCAL USE The AV102SS may be used to call out to a remote monitoring centre using the ADPRO remote transmitters (FastScan, FastVu or FastTrace). If a local handset is required for use during manned hours, the system should be...
Page 9
Please check that you have the all of the following items which are included in the kit:- 1 X SWITCHING PCB (102PAIR1 REV 1.1) 4 X 20mm TYPE 4 PCB PILLAR 8 X M3 FULL NUT 8 X M3 PLAIN WASHER DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 8 of 22...
Page 10
BNC connector on the existing main PCB. Place an M3 plain washer on to the studs which now protrude through the new PCB and screw an M3 full nut on to each. DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 9 of 22...
Page 11
"A CALL” and the terminals marked “B CALL" are reversed. These terminals have been re-labelled at the factory and the drawing below shows the correct layout. Switching DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 10 of 22...
Page 12
TO UNIT B "O/P+" VIDEO A VIDEO SIGNAL FROM CAMERA IN UNIT A VIDEO B VIDEO SIGNAL FROM CAMERA IN UNIT B VIDEO OUT VIDEO SIGNAL OUTPUT (TRANSFORMER ISOLATED) DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 11 of 22...
Page 13
CONNECTING THE SYSTEM : WIRING DIAGRAM This diagram shows the wiring for a master/slave combination, with COMMON CALL enabled and feeding an ADPRO remote transmission system. DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 12 of 22...
Page 14
INSTALLING MULTIPLE AV102 INTERCOMS : AUTO-ZONING USING ADPRO REMOTE TRANSMITTER AND AVS BINREL02 SWITCHER If you wish to use many AV102SS intercoms on a site, you may connect the AVPSU4 units (which come with each AV102SS intercom) as shown in the diagram below.
Page 15
If you wish to use many AV102SS intercoms on a site, you may also connect the system without any AVPSU4 units as shown in the diagram below. The advantage of this configuration is that the wiring is easier, as there are no AVPSU4s to install or connect, no “D”...
Page 16
Finally, adjust the control on the MAIN intercom PCB marked "R19" (OUTPUT LEVEL) to give the required overall output level to the speaker. DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 15 of 22...
Page 17
DETAIL OF MECHANICAL FIXINGS FOR INTERCOM MESSAGE CARD DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 16 of 22...
Page 18
ABOUT THE AVPSU4 POWER SUPPLY & INTERFACE UNIT All AV102SS intercom unit built after March 2000 are supplied with an AVPSU4 unit. Below is a description of the indicators and connections, and their functions:- Refer to the parts identification drawing POWER OUTPUT TERMINALS (1) These terminals provide a 24 Volt DC power output to power the call-point.
Page 19
(RCA Jack) connectors OR the terminal connectors on the rear panel. NOTE : Duplex (simultaneous two-way) audio is always enabled on the AV102SS. It is NOT necessary for the caller to press the push-button to speak. This button is only used to initiate the call.
Page 20
The Advanced Visual Solutions AV102 series of intercoms use this unit as both a power supply source and an audio interface. These intercoms have their push-buttons isolated from the cables by means of an internal opto-isolator device. It is most important to maintain the correct polarity of the cables between the AV102 and the AVPSU4 units.
TECHNICAL SUPPORT Advanced Visual Solutions Ltd provide full technical support for our products. We have two, fully equipped “central station” workstations, running the latest version of ADPRO video central gold software. We can therefore connect to ADPRO remote transmitters, providing that they are on standard PSTN telephone lines (modem), standard ISDN lines (terminal adapter) or standard ADSL (broadband) connections.
Page 22
TOP VIEW NOTES 3mm Drain holes in bottom Dimension of intercom faceplate:- H =265mm W=140mm 6 X Mounting holes in faceplate as shown on backbox front view above left. DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page 21 of 22...
D = 105mm (excluding connectors) As a consequence to our ongoing policy to improve and/or increase the quality and flexibility of our products, Advanced Visual Solutions Ltd reserve the right to change the specification or appearance of products without prior notice.