INSTALLATIONS
INSTALLATIONS
Standard Parts:
Insert
Deadbolt Keeper
Deadbolt Plug
Deadlatch Ramp (Auxiliary Bolt Bracket)
Keeper Sliding Shims: 1/16" (1.5mm) and 1/8" (3.0mm)
A Centerline Latch Faceplate and an Offset Latch Faceplate are provided.
Both are: 4-7/8" x 1-1/4" (123.8mm x 31.8mm)
Trim Plate
12VDC or 12 to 24VAC Cable Connector
24VDC Cable Connector
Anti-Tamper Security Screws (2x 12-24) and Bit
Mounting Tab Kit (2x tabs, 4x shims and 5x 12-24 screws)
Inductive Kickback Suppressor - MOV
*Warning: The fire and security ratings shown on the strike labels no longer apply with the use of this faceplate.
The F2164 fail secure locking mechanism shall only be installed where allowed by the local authority having jurisdiction and shall
not impair the operation of the panic hardware or intended operation of the emergency exit.
Wiring Instructions
Use the appropriate wire harness supplied.
12V for 12VDC & 12-24VAC
24V for 24VDC only
Attach the red wire to (+) positive of the power supply.
Attach the black wire to the (–) negative of the power supply.
If using AC power, polarity is not observed.
To meet BHMA A156.31, install the MOV provided across the
positive and negative wires or terminals of the harness. The MOV
is not polarity sensitive.
NOTE: If a suppression diode is required for access control,
observe proper polarity.
Latch Monitor Wires
Black
= Common (C)
Blue
= Normally Closed (NC)
Orange = Normally Open (NO)
These strikes must be connected to a compatible UL Listed Burglary or Access Control Power Supply.
ISF2
WWW.RUTHERFORDCONTROLS.COM • PHONE: 1.800.265.6630 • FAX: 1.800.482.9795 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM
Red
+
© 2016 RUTHERFORD CONTROLS INT'L | A DORMA GROUP COMPANY
Fail Locked F2164
& Fail Unlocked 2364
Accessories:
Latch Monitor Switch : F2LM
9" Centerline Latch Entry Faceplate : F2-19*
9" Offset Latch Entry Faceplate : F2-29*
Filler Plate - 2 Series Strike : 2FP
UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I
24VDC
Terminal
12VDC
12-24VAC
Black
Terminal
Red
-
+
Black
-
Latch
Monitor
Optional LM
Wiring the 2 Series Electric Strike
(Fire-Rated)
ELECTRIC STRIKE
PCN15058
R06/16GR

Advertisement

loading

Summary of Contents for RCI F2164

  • Page 1 *Warning: The fire and security ratings shown on the strike labels no longer apply with the use of this faceplate. The F2164 fail secure locking mechanism shall only be installed where allowed by the local authority having jurisdiction and shall not impair the operation of the panic hardware or intended operation of the emergency exit.
  • Page 2 Fail Locked F2164 (Fire-Rated) & Fail Unlocked 2364 Installation Instructions (Continued) Mount the strike into the frame without the faceplate. Tighten the mounting screws just enough to hold the strike in place; you may need to slide it up-down for adjustment.
  • Page 3 Fail Locked F2164 (Fire-Rated) & Fail Unlocked 2364 Installation Instructions (Continued) Adjust Plug-in Latch Monitor (Accessory): First, move the door towards the strike so that the latch touches the keeper. Mark latch limit lines on keeper. Then, open the door. Mount the Latch Monitor on the strike housing so that it is between the latch limit lines marked on keeper.
  • Page 4 Fail Locked F2164 (Fire-Rated) & Fail Unlocked 2364 Installation Instructions (Continued) Keeper Sliding Shim Horizontal Adjustment: If there is play in the door when closed; the keeper shims may be used to minimize play. Bend tabs to grip frame Trim Plate: This can be used in case the frame cutout is bigger than required.

This manual is also suitable for:

2364