Page 1
TN52J-E3252 Service Engineer’s Manual http://www.tyan.com...
Page 2
MiTAC assumes no liability whatsoever, and ® disclaims any express or implied warranty, relating to sale and/or use of TYAN products including liability or warranties relating to fitness for a particular purpose or merchantability. MiTAC retains the right to make changes to produce descriptions and/or specifications at any time, without notice.
Page 3
Classe A est conforme à la norme NMB-003 du Canada. Notice for Europe (CE Mark) This product is in conformity with the Council Directive 2014/30/EU. Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. http://www.tyan.com...
How this guide is organized This guide contains the following parts: Chapter 1: Overview This chapter provides an introduction to the TYAN TN52J-E3252 storage system and standard part list, describes the external components, gives an overview of the product from different angles.
Page 5
Safety and Compliance Information Before installing and using TYAN TN52J-E3252, take note of the following precautions: ·Read all instructions carefully. ·Do not place the unit on an unstable surface, cart, or stand. ·Do not block the slots and opening on the unit, which are provided for ventilation.
You must become familiar with the safety information in this guide before you install, operate, or service TYAN products. Symbols on Equipment Caution. This symbol indicates a potential hazard.
Page 7
· Make sure the stabilizing feet are attached to the rack if it is a single-rack installation. · Make sure racks are coupled together if it is a multiple-rack installation. · Make sure the rack is level and stable before installing an appliance in the rack. http://www.tyan.com...
Page 8
· In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do not ground the Green/Yellow tab, it can cause an electrical shock due to high leakage currents. http://www.tyan.com...
Page 9
· To reduce the risk of electrical shock, disconnect all power cords before servicing the appliance. Equipment Modifications · Do not make mechanical modifications to the system. TYAN is not responsible for the regulatory compliance of TYAN equipment that has been modified.
Table of Contents Chapter 1: Overview............... 13 About the TYAN TN52J-E3252 ..........13 Features .................. 14 About the Product ..............15 1.3.1 System Front View ............15 1.3.2 Front User OP Panel ............16 ...
It provides a maximum data protection and exceptional performance in a storage subsystem. Target usage ranges are set from small business to departmental and corporate server needs. The JBOD TN52J-E3252 is designed for easy integration, smooth data expansion and server migration. ®...
About the Product The following views show you the product from different angles. 1.3.1 System Front View Description (24) 2.5” hot-swappable HDD trays Front User OP Panel NOTE: A discrete HBA/RAID adapter is required to enable all drives. HDD/SSD Sequence http://www.tyan.com...
500 ms OFF Power off 3. System Status If possible, SAS expander is booting; 1Hz±0.1Hz repeating Green: Okay, sequence with equal ON and OFF Slow Blinking (if possible) Operational time. (515-535nm) NOTE: During the firmware download process, the Green: http://www.tyan.com...
Page 17
(identifying the status of default display lowercase letters of the English devices) value is "Blank".) alphabet can be portrayed. It helps user or administrator identify the status of devices. There are three 7-segment devices on product displaying with blank or hexadecimal value. http://www.tyan.com...
Green: Okay, during activity. The blink pattern Feedback Flash / Activity Operational must be random, but if it is Blink (515-535nm) inadvertently set to a fixed rate, recurring pattern, then it must not blink > 2 < 55 Hz. http://www.tyan.com...
RJ45 Management LAN Port (for service only) IOM System Summary Status Indicators IOM Module Status Indicators Mini-SAS HD Connector (Port 0) Mini-SAS HD Connector (Port 1) Mini-SAS HD Connector (Port 2) Mini-SAS HD Connector (Port 3) IOM SAS Port Status Indicators http://www.tyan.com...
Normal operation; no service or fault states in system. Amber: Service System has a fault; service action Action Required Steady ON required within system. (585-595nm) 3. System Status Power off Green: Okay, Steady ON System is operational. Operational (515-535nm) http://www.tyan.com...
Steady ON controller. Amber: Service Fast Blinking Action Required 2Hz at 50% duty cycle: Controller locate function. (585-595nm) 250 ms ON 250 ms OFF 3. Controller Status No power to the controller. Green: Okay, Controller is operational. Operational (515-535nm) http://www.tyan.com...
1.3.7 SAS Port Indicators State/Color Description 1. Fault LED One or more links failure: amber ON Link not at 12G speed Link Off-Line: green OFF No cable present 2. Link/Activity LED Link Ready: green solid ON No data traffic http://www.tyan.com...
4. PSU Fault LED System has detected a fault in the Amber: Service Steady ON power supply. Action Required and Locate Fast Blinking (585-595nm) 2Hz at 50% duty cycle: Power supply locate function. 250 ms ON 250 ms OFF http://www.tyan.com...
Caution! To avoid damaging the motherboard and associated components, do not use torque force greater than 7kgf/cm (6.09 lb/in) on each mounting screw for motherboard installation. Do not apply power to the board if it has been damaged. http://www.tyan.com...
Working on a system that is connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to TN52J-E3252 or injury to yourself. Ground yourself properly before removing the top cover of the system. Unplug the power from the power supply and then touch a safely grounded object to release static charge (i.e.
Unpacking & Checking the Equipment This section describes TN52J-E3252 package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. If any items are missing or appear damaged, contact your retailer or browse to TYAN’s website for service:...
Push the locking lever latch to pull the HDD tray out. Unscrew to remove the bracket from the HDD tray. Place a 2.5" hard drive into the HDD tray and secure the HDD/SSD with 4 screws. http://www.tyan.com...
Page 29
Reinsert the HDD tray into the chassis and press the locking lever latch to secure the HDD tray. Repeat the same procedures to install other HDD trays. http://www.tyan.com...
TN52J-E3252 barebone which may not look exactly like the rackmount storage you purchased. Therefore, the illustrations should be held for your reference only. After installing the necessary components, the TYAN TN52J-E3252 can be mounted in a rack using the supplied rack mounting kit. Rack mounting kit...
Page 31
Lift the unit and then engage the sides of the unit with the installed side rails. Push the whole system into the rack. Secure the whole system to the rack with 4 screws. http://www.tyan.com...
Chassis Expansion This section shows chassis expansion possibilities with one or more JBOD storage systems. Please contact Tyan techinical support for expander FW that supports share storage or other IN/OUT port configurations. 2.4.1 SAS In-Out Port Configuration (Volume Expansion) Connect one end of the External mini-SAS HD cable (SFF 8644) to the HBA card port on the Server and the other end to the SAS port on JBOD.
RAID system is involved in configuration. 3. Power on and boot the host computer. Turning Off When turning off JBOD system, users are advised to first shut down the host computer, then power off RAID system, finally power off JBOD system. http://www.tyan.com...
Power Supply Unit to OFF position before you follow these instructions to replace the power supply units. Press and hold the side latch while pulling the power supply out from the chassis. Slide to remove the old power supply. Then install the new power supply. http://www.tyan.com...
Replacing the IOM Follow the instructions to remove the I/O Module (IOM). Unlock the locking lever latch and pull the locking lever open. Slide to remove the old IOM. Then install the new IOM all the way into the chassis. http://www.tyan.com...
Removing the Cover Before replacing any parts you must remove the chassis cover. Follow the instructions to remove the cover of the TN52J-E3252. Remove all IOMs and PS Modules. Loosen 8 screw on the top cover and both sides. http://www.tyan.com...
Page 40
Slide the rear top cover to lift it up. http://www.tyan.com...
Replacing the Mid-plane Follow these instructions to replace the Mid-plane. Loosen 6 screws on the Mid-plane Push the Front Panel Connector latch to an open position. Unplug the Front Panel Cable. http://www.tyan.com...
Page 42
After replacing a new Mid-plane, follow the procedures described earlier in reverse order to reinstall the Mid-plane. http://www.tyan.com...
Appendix I: FRU Parts Table TN52J-E3252 FRU Parts Item Model Number Part Number Picture Description Power Supply+Fan FRU-PS-0200 471100000310 580W PSU+Fan Rack Mounting Parts FRU-AS-0070 452T57300001 Rail Kit AC Power Cord, US type FRU-CS-0330 332810000514 L=1800mm ACPower Cord, EU type...
JBOD: Just a Bunch Of Disks, an architecture involving multiple hard drives, while making them accessible as independent hard drives. http://www.tyan.com...
MiTAC serves multiple market segments with the industry’s most competitive services to support them. Please feel free to contact us directly for this service at tech-support@tyan.com Help Resources: 1. See the TYAN’s website for FAQ’s, bulletins, driver updates, and other information: http://www.tyan.com...
Page 48
(RMA) number. The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid. TYAN will pay to have the board shipped back to you. TYAN® TN52J-E3252 Service Engineer’s Manual V1.0 Document No.: D2375-100 http://www.tyan.com...
Need help?
Do you have a question about the TN52J-E3252 and is the answer not in the manual?
Questions and answers