b. MOUNTING INSTRUCTIONS
• Remove the mounting plate from the back of detector (slide to the unlock
position to remove).
• Select the proper detector location as described in section 3.
• Connect the Quick Connector for power and relay as described in the WIRING
REQUIREMENTS.
• For models STCH-1000HW and STCH-1000HWR, secure the mounting plate
to the electrical box using the appropriate holes (see Figure 4). For model
PSM-011, which is designed to be wall mounted, use the enclosed screws and
anchors to fasten the mounting plate on the wall 5 to 6 feet above the floor.
• Pull the Quick Connector through the center hole in the mounting plate.
• Plug the mating halves of Quick Connector with the same color of wires
together.
• Slide the detector on the mounting plate to the lock position.
• Turn on the power and the green
receiving power.
After installation, TEST your detector by pressing and holding the
button for several seconds. Complete instructions regarding testing are outlined
in section 7.
Rectangular
Octagonal
Electrical Box
Electrical Box
(Use holes
(Use diagonal
Set "C")
holes: Set "A"
or Set "B")
FIGURE 4: ELECTRCAL BOXES AND MOUNTING PLATE
POWER ON
"B"
"C"
"A"
UP
MOUNTING PLATE ORIENTATION
FOR W ALL MOUNTING
- 6 -
indicator should be lit for
TEST/RESET
"A"
Rectangular
"C"
plaster ring
"B"
Circular
plaster ring