INSTALLATION, OPERATING
& SERVICE INSTRUCTIONS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED
BY PROFESSIONAL PERSONNEL AS SPECIFIED.
For Your Safety:
Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be
obtained by consulting your local gas supplier.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine
Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,
adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided
with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified
or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer
to the Garland web site at http://www.garland-group.com. The information contained herein, (including design and parts
specifications), may be superseded and is subject to change without notice.
Continuous product improvement is a Garland policy, therefore design and specifications are subject to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 4519762 (01/05)
Part # 4519762 (01/05)
FOR GARLAND
GD SERIES
GAS COUNTER UNITS
GARLAND COMMERCIAL RANGES,
LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
READ THE INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
Enodis UK LTD.
Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
© 2005 Garland Commercial Industries, Inc.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GD-152H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Garland GD-152H

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified...
  • Page 2: Important Information

    IMPORTANT INFORMATION WARNING: This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the State of California to cause cancer.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS IMPORTANT INFORMATION ......................2 SPECIFICATIONS ..........................4 PRE INSTALLATION ......................... 4 Damage Check ............................4 Rating Plate ..............................4 INSTALLATION ..........................5 General ..............................5 Clearances ..............................5 Gas Connections ............................5 Installation of Banking Plates ........................6 Installation of Non-Combustible Counter Stands (Optional) ..............
  • Page 4: Specifications

    Garland / U.S. Range will not provide service, warranty, The correct type of gas for which the unit was maintenance or support of any kind other than in manufactured is noted on the rating plate, and this type commercial applications.
  • Page 5: Installation

    INSTALLATION General Clearances 1. Carefully remove unit from carton or crate. Burner MINIMUM INSTALLATION CLEARANCES TO tie wires and other packing material should be ADJACENT COMBUSTIBLE/NON-COMBUSTABLE removed from units. On stainless steel units, the WALLS OR BASE protective material covering the stainless steel Sides &...
  • Page 6: Installation Of Banking Plates

    INSTALLATION Continued 2. The correct type of gas for which the unit was are available for each unit to be installed. One at the manufactured is noted on the rating plate, and this front and one at the rear of each two units being banked type of gas must be used.
  • Page 7: Installation Of Non-Combustible Counter Stands (Optional)

    INSTALLATION Continued Installation of Non-Combustible ideal method of ventilating counter equipment is the use of a properly designed ventilating canopy, which Counter Stands (Optional) should extend at least 6”/152mm beyond all sides of 1. Assemble and level counter stand as illustrated in the appliance (except against the wall if the canopy is a the instructions found in the counter stand carton.
  • Page 8: Hot Plates

    ADJUSTMENTS Continued Hot Plates Pilot Burner Adjustment 1. Turn thermostat knob to lowest position. IMPORTANT: The flue must be installed prior to start-up. 2. Depress and turn automatic gas valve knob to “OFF” position. Caution: Wait 5 minutes before Pilot Burner Adjustment lighting or relighting pilot.
  • Page 9: Calibration Instructions

    ADJUSTMENTS Continued Calibration Instructions For the griddle equipped with thermostats the pilot and the main burner are controlled by the ON-OFF valve. 1. Field calibration is seldom necessary and should not MAKE SURE THE THERMOSTAT IN ON OFF be attempted unless experience with cooking results POSITION.
  • Page 10: Broilers

    MODEL DESCRIPTION PILOT FLAME IMPORTANT: The flue must be installed prior to NUMBER LENGTH start-up. GD-152H(FF) Hot Plate 1/2” [13 mm] Pilot Burner Adjustment GD-302H(FF) Hot Plate 1/2” [13 mm] GD-304H(FF) Hot Plate 1/2”...
  • Page 11: Operation For "Ff" Models

    OPERATION FOR “FF” MODELS Open Type Hot Plate 3. When the pilot is lit, continue to hold the tap in for 20 seconds, then release it. If the pilot goes out, All burners are equally rated and may be used either for wait for 5 minutes, then repeat from step 1.
  • Page 12: Maintenance Instructions

    Stainless scouring pad in combination with a “Regular Maintenance Ensures Peak Performance.” powdered cleanser. PARTS AND SERVICE It is easy to keep your Garland equipment working in Technical information and/or parts literature is available top condition. through your local Authorized Garland Service Agency...
  • Page 13 NOTES Part # 4519762 (01/05) Page 13...
  • Page 14 NOTES Page 14 Part # 4519762 (01/05)
  • Page 15 NOTES Part # 4519762 (01/05) Page 15...