Educational Services; Installation - Emerson Fisher EZ-C Instruction Manual

Table of Contents

Advertisement

Instruction Manual
D102175X012
Table 2. Maximum Allowable Actuator Thrust for Standard Style 3 Bonnet Extension Length
VALVE SIZE, NPS
1
1-1/2
2
3
4, 6X4, 8X4
6, 8X6, 12X6
8, 10X8

Educational Services

For information on available courses for Fisher EZ-C, ET-C, and EWT-C valves, as well as a variety of other products,
contact:
Emerson Automation Solutions
Educational Services - Registration
Phone: 1-641-754-3771 or 1-800-338-8158
E-mail: education@emerson.com
emerson.com/fishervalvetraining

Installation

Isolate the control valve from the line pressure, release pressure from both sides of the valve body, and drain the
process media from both sides of the valve. Remove actuator supply pressure, and use lockout procedures to be sure
that the above measures stay in effect while you work on the equipment. Refer to the Warnings at the beginning of the
Maintenance section for additional information.
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
Personal injury or equipment damage caused by sudden release of pressure may result if the valve assembly is installed
where service conditions could exceed the limits given in table 1 or on the appropriate nameplates. To avoid such injury or
damage, provide a relief valve for over‐pressure protection as required by government or accepted industry codes and
good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
STEM DIAMETER
mm
Inches
9.5
12.7
9.5
12.7
12.7
19.1
12.7
19.1
12.7
19.1
19.1
25.4
19.1
25.4
MAXIMUM ALLOWABLE STEM LOAD
FOR S20910 (XM‐19) STEM MATERIAL
3/8
5382
1/2
13166
3/8
5338
1/2
13166
1/2
14367
3/4
44169
1/2
15301
3/4
45459
1/2
16458
3/4
46971
3/4
36385
1
81487
3/4
41366
1
87003
EZ-C, ET-C, and EWT-C Valves
N
Lb
1210
2960
1200
2960
3230
9930
3440
10220
3700
10560
8180
18320
9300
19560
July 2017