Sandel ST3400H HeliTAWS Installation Manual page 33

Terrain awareness warning system
Hide thumbs Also See for ST3400H HeliTAWS:
Table of Contents

Advertisement

Ground Bonding. Bonding of the ST3400H shall be in accordance with AC 43.13-1B,
Chapter 11, Section 15. After installation, bonding shall be measured and the result shall be 10
milliohms or less between the ST3400H case and the instrument panel.
Power Wiring. To assure that the ST3400H will operate properly down to its rated minimum
input voltage, ensure that two power wires of at least the recommended size are connected in
accordance with the installation drawings.
82046-IM-K
ST3400H INSTALLATION MANUAL
Page 4-6

Advertisement

Table of Contents
loading

Table of Contents