  • Page 1 2 innkeeper 4 Multi Line Digital Hybrids User Guide JK Audio...
  • Page 2 Ready to go? The innkeeper 2/4 features diagrams will help you pinpoint any minor questions that you may have. If this is your first exposure to a hybrid, we suggest that you read the entire manual to allow you to take advantage of all these features.
  • Page 3 10. Conference button - Use this feature to conference together lines 1 and 2 when both lines are off-hook. This feature is available on innkeeper 2 only. 11. Monitor Handset Jacks - Used to connect an electret type hand- set for communication on the corresponding phone line.
  • Page 4 Off-Hook signal pin and a Call/Drop control pin for each channel. See pages 8-9. This jack can also be used for connection to the optional JK Audio RIU-IP remote interface (see page 16) 18. AC connector - For connection to 120 - 240 VAC, 50-60 Hz...
  • Page 5 The innkeeper 2 was used in this exam- ple. Follow the same strategy for an innkeeper 4, with 4 Aux Send buses.
  • Page 6: Operation

    You can use an auxiliary telephone to place or screen a call, and then the call can be placed on hold. When you are ready to take the call on innkeeper 2/4, simply press the Call button for the corresponding phone line. Your telephone will automatically release the hold while you talk.
  • Page 7 DSP. The LED will display receive signal levels at -20 dB as green up to -3 dB where it will change to red. The innkeeper 2/4 menu will allow you to adjust individual Caller output levels in 1 dB increments over a +/-10 dB range to give you the best signal level at your equipment.
  • Page 8: Remote Jack

    Remote Jack Remote Jack The 10 pin RJ-50 jack on the back of the innkeeper 2/4 pro- vides a proprietary connection to the supplied remote terminal block. A 1 meter cable is provided for this connection. This jack can also be used to connect to the optional JK Audio RIU-IP remote interface see page 16).
  • Page 9 Remote Terminal Block Operation (continued) Terminal Block Pinout L1-ST L1-CNT L2-ST L2-CNT L3-ST L3-CNT L4-ST L4-CNT Terminal Terminal Description Number Ground Line 1 - OH status signal (nominal +5Vdc @ 50ma, when active) Line 1 - OH control (momentary to grd toggles lineon/offhook)* Line 2 - OH status signal (nominal +5Vdc @ 50ma, when active) Line 2 - OH control (momentary to grd toggles lineon/offhook)* Line 3 - OH status signal (nominal +5Vdc @ 50ma, when active)
  • Page 10: Operation - Menu Display

    Operation - Menu Display Backlit Menu Display and Controls The innkeeper 2/4 menu is controlled by the directional arrows, alpha numeric keypad and Enter button. You may use either the arrow keys to scroll through the menus or the keypad to di- rectly select menus and use the Enter button or the keypad to make your selections.
  • Page 11 Operation - Menu Display (continued) Operation (continued) intent to clear the entire phone book before deletion. Call History (2) Calls you place will automatically be entered into the Call History menu. The Call History menu will hold up to 16 numbers. Call History View (2,1) Allows you to view name and phone numbers of automatically added entries.
  • Page 12 This tone is only for your conven- ience in setting your equipment audio levels. Conference (3,5) innkeeper 2 only. This menu allows you to configure settings for the Conference feature. See pages 14-15 Conf. Send Mix Mode (3,5,1) innkeeper 2 only. Configure the Send Mix Mode to "Send Mix"...
  • Page 13 Operation - Menu Display (continued) Operation (continued) both Caller output jacks. Caller 1 and Caller 2 outputs will con- tain both Line 1 and Line 2 caller audio. The "Full Mix Minus" option provides a mix-minus signal output on both Caller output jacks.
  • Page 14 Operation - Conference (innkeeper 2 only) Conference One press of the conference button will join the audio paths of both line one and line two, provided there are calls present on both lines. A second press of the conference button will break the audio paths be- tween the calls.
  • Page 15 Operation - Conference Options Operation (continued) Advanced Conference Options Signal Flow Diagrams...
  • Page 16 RIU-IP The JK Audio Remote Interface Unit was designed for use with inn- keeper 1x/1rx as well as innkeeper 2 and innkeeper 4 digital hybrids. This unit contains a web server which allows the user to send and receive control data through their web browser. RIU-IP can be con-...
  • Page 17: Specifications

    Specifications Operation (continued) Inputs: Line: Balanced Female XLR, 20k ohm, +10 dBu max Master Send: Balanced Female XLR, 20k ohm, +10 dBu max Outputs: Line: Balanced Male XLR, 200 ohm, +14 dBu max Handset: Front panel handset jacks biased for electret handset (not included) Phone Line: RJ11C Aux Phone:...
  • Page 18: Fcc Part 15 Compliance

    Changes or modifications not expressly approved by JK Audio can void the user's authority to operate the equipment. FCC Registration Your new JK Audio product has been registered with the Federal Communications Commission (FCC). This product complies with the standards in Part 68 of the FCC rules.
  • Page 19 FCC. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper functioning of your JK Audio product. If such changes are planned, you'll be notified by your telephone company.
  • Page 20: Warranty

    Innkeeper 2/4 is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the innkeeper 2/4 needs repair, you must call us to get an authorization, and then carefully pack and ship it to us.

This manual is also suitable for:

Innkeeper 4

Table of Contents