Blower Performance - Intertek GPG 16 SEER Installation Instructions Manual

Single package gas-electric heating & cooling units
Table of Contents

Advertisement

BLOWER PERFORMANCE DATA
T1 LOW STAGE HEATING
E.S.P.
CFM
625
0.1
0.2
585
550
0.3
495
0.4
0.5
445
400
0.6
345
0.7
0.8
----
T1 LOW STAGE HEATING
E.S.P.
CFM
1,035
0.1
990
0.2
950
0.3
0.4
910
865
0.5
820
0.6
0.7
765
0.8
725
T1 LOW STAGE HEATING
E.S.P.
CFM
950
0.1
895
0.2
840
0.3
775
0.4
710
0.5
650
0.6
0.7
590
0.8
540
T1 LOW STAGE HEATING
E.S.P.
CFM
1,100
0.1
1,040
0.2
985
0.3
920
0.4
875
0.5
0.6
815
765
0.7
0.8
710
T1 LOW STAGE HEATING
E.S.P.
CFM
1,085
0.1
1,035
0.2
985
0.3
925
0.4
870
0.5
815
0.6
760
0.7
0.8
710
X = Outside of Temperature Rise Range Not Recommended.
NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,
external static pressure should not
GPG1624060M41** - Rise Range: 35° - 65°
T2 HIGH STAGE HEATING
SPEED
SPEED
WATTS
RISE
CFM
WATTS
53
54
855
107
61
58
815
114
70
61
785
125
78
X
750
135
85
X
705
141
93
X
660
149
99
X
615
157
----
----
570
166
GPG1630080M41** - Rise Range: 35° - 65°
T2 HIGH STAGE HEATING
SPEED
SPEED
WATTS
RISE
CFM
WATTS
156
43
1,300
287
165
45
1,265
293
173
47
1,220
310
184
49
1,190
306
190
52
1,145
319
200
55
1,105
320
204
59
1,070
330
211
62
1,015
338
GPG1636080M41** - Rise Range: 35° - 65°
T2 HIGH STAGE HEATING
SPEED
SPEED
WATTS
RISE
CFM
WATTS
115
47
1,245
230
124
50
1,195
238
134
54
1,150
247
146
58
1,095
256
152
63
1,045
263
160
X
990
277
163
X
935
285
171
X
870
288
GPG1642100M41** - Rise Range: 35° - 65°
T2 HIGH STAGE HEATING
SPEED
SPEED
WATTS
RISE
CFM
WATTS
172
51
1,420
325
181
54
1,360
331
185
57
1,310
342
193
61
1,275
353
203
64
1,210
360
207
X
1,165
368
215
X
1,115
369
216
X
1,075
385
GPG1648100M41** - Rise Range: 35° - 65°
T2 HIGH STAGE HEATING
SPEED
SPEED
WATTS
RISE
CFM
WATTS
171
52
1,410
326
178
54
1,365
329
184
57
1,315
337
193
61
1,270
353
198
65
1,220
360
208
X
1,175
372
213
X
1,115
375
219
X
1,080
381
exceed 0.8"
w.c.
T3 LOW STAGE
T4 HIGH STAGE
COOLING SPEED
COOLING SPEED
RISE
CFM
WATTS
CFM
53
625
51
850
55
590
60
810
57
555
68
775
505
79
735
60
64
450
86
705
410
93
655
X
330
101
600
X
X
----
----
565
T3 LOW STAGE
T4 HIGH STAGE
COOLING SPEED
COOLING SPEED
RISE
CFM
WATTS
CFM
46
945
130
1,095
47
905
136
1,055
49
865
143
1,020
50
815
152
970
770
160
930
52
715
173
885
54
56
660
173
840
59
610
183
785
T3 LOW STAGE
T4 HIGH STAGE
COOLING SPEED
COOLING SPEED
RISE
CFM
WATTS
CFM
48
1,045
149
1,280
50
990
160
1,225
52
935
167
1,180
875
179
1,130
55
820
186
1,085
57
755
194
1,030
61
64
700
197
975
X
650
214
920
T3 LOW STAGE
T4 HIGH STAGE
COOLING SPEED
COOLING SPEED
RISE
CFM
WATTS
CFM
53
1,075
162
1,335
55
1,015
172
1,290
57
960
185
1,230
900
188
1,185
59
845
200
1,130
62
64
790
208
1,075
740
211
1,030
X
X
680
217
980
T3 LOW STAGE
T4 HIGH STAGE
COOLING SPEED
COOLING SPEED
RISE
CFM
WATTS
CFM
53
1,225
227
1,475
55
1,190
240
1,430
57
1,120
246
1,375
1,070
254
1,320
59
1,015
266
1,270
61
970
265
1,230
64
920
279
1,185
X
X
875
280
1,140
25
T5 COOLING SPEED
WATTS
CFM
WATTS
104
1,090
197
116
1,055
201
122
1,020
207
129
995
212
136
955
230
147
915
240
154
880
255
160
835
246
T5 COOLING SPEED
WATTS
CFM
WATTS
185
1,295
289
195
1,260
294
202
1,220
304
210
1,180
313
215
1,140
319
222
1,105
326
233
1,055
334
234
1,015
337
T5 COOLING SPEED
WATTS
CFM
WATTS
258
1,440
354
259
1,390
365
274
1,355
369
280
1,300
383
293
1,260
396
295
1,210
402
304
1,160
397
315
1,110
415
T5 COOLING SPEED
WATTS
CFM
WATTS
274
1,620
484
288
1,575
489
297
1,530
497
304
1,490
500
321
1,450
507
321
1,405
518
325
1,345
516
330
1,300
528
T5 COOLING SPEED
WATTS
CFM
WATTS
367
1,790
641
366
1,745
650
378
1,710
659
383
1,670
663
397
1,625
674
400
1,585
672
409
1,540
675
417
1,495
683

Advertisement

Table of Contents
loading

This manual is also suitable for:

M series

Table of Contents