Wiring Diagram - Intertek GPG 16 SEER Installation Instructions Manual

Single package gas-electric heating & cooling units
Table of Contents

Advertisement

GPG16*****M41A** WIRING DIAGRAM
YL
HPS
S
COMP
R
C
YL
BK
YL
BR
PU
SOL
CM
BK
GR
BL
PU
C
N
G
L
EM
T1
T2
T3
T4
T5
VM
W H
PU
BL
BR
PU
YL
IGN
FS
RD
OR
LS
OR
YL
PS
YL
ALS
PU
PU
1
2
RS
PU
1
2
PU
M
GV
W . R.
H
BR
GAS VALVE
C
BL
COMPONENT LEGEND
FACTORY W IRING
ALS
AUXILLARY LIMIT SW ITCH
LINE VOLTAGE
CC
CONTACTOR
LOW VOLTAGE
CM
CONDENSER MOTOR
OPTIONAL HIGH VOLTAGE
COMP
COMPRESSOR
EM
EVA PORATOR MOTOR
FIELD WIRING
FUSE
F
HIGH VOLTAGE
FS
FLAME SENSOR
LOW VOLTAGE
GND
EQUIPMENT GROUND
GV
GAS VALVE
W IRE CODE
HPS
HIGH PRESSURE SW ITCH
BK BLACK
IGNITOR
IGN
BL BLUE
INTEGRATED IGNITION CONTROL
IIC
BR BROW N
LS
LIMIT SW ITCH
GR G REEN
ODF
OUTDOOR FAN
GY GRAY
PS
PRESSURE SW ITCH
OR O RANGE
RCCF
RUN CAPACITOR FOR COMPRESSOR/FAN
PK PINK
RS
ROLLOUT SW ITCH
PU PURPLE
SOL
SOLENOID (2ND STAGE COOL)
RD RED
TRANSFORMER
TR
W H W HITE
VM
VENT MOTOR
YL
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
M
ULTIPLE POWER SOURCES MAY BE PRESENT
SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH
YL
PU
YL
RD
RD
BK
T1
T2
BL
L1
L2
CC
BK
PU
BL
BK
SEE NOTE 2
1
2
3
C
208
240
PU
TR
BK
24V
BL
RD
BL
RD
BK
PU
PU
BK
RD
PU
BK
BK
PU
BL
BK
BK
BK
OR
L2
LOW
HIGH
L1
LOW
HI
ODF
INDUCER
T1
FS
SEE
NOTE 4
PU
5
LO COOL
YL
6
3
BL
4
24VAC COM
5
2
4
1
YL
3
HI COOL
YL
2
BR
HI HEAT
P1
W H
1
LO HEAT
BL
BR
OR
1
4
7
YL
2
5
8
PU
OR
3
6
9
SEE NOTE 5
180
F
NO N E
150
5 MI N
120
10 MI N
90
B LO W E R
S T A G E
C
W1
W2
R
G
Y1
Y2
ECON
O FF DE LAY
DE LA Y
RD
YL
YL
PU
NOTES
1. REPLACEMENT W IRE MUST BE THE SAME SIZE AND TYPE O F
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK W IRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. USE COPPER CONDUCTORS ONLY
4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW
TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO
INDUCER LOW TERMINAL. PLACE BLUE LEAD ON PARK TERMINAL.
5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD W IRING.
YELLOW
D
ALL
ISCONNECT
YL
YL
GND
SEE NOTE 3
PU
YL
POW ER SUPPLY
208-230/1/60
SEE NOTE 3
PU
YL
RD
YL
YL
PARK
PU
YL
P2
YL
RD YL
BR
C
F
H
RCCF
0140G03218-A
23
.
POWER BEFORE SERVICING
. F
AILURE TO DO
.
L1
SUPPLY VOLTAGE
208-230/1/60
CC
T1
L1
R
C
COMP
L1
S
H
LO
HI
CM
LO
SEE NOTE 4
VM
HI
L1
EM
1
2
L1
F
P1
TH
2
LS
HLO
1
HLI
R
3
PS
PSW
6
W1
PSW
8
W2
ALS
RS
MVL
TO
9
MICRO
MVH
Y2
7
C
5
P2
COM
Y1
1
4
HPS
5
3
6
2
SOL
SOL
ECON
LO HEAT
HI HEAT
T2
G
TO
LO COOL
MICRO
T3
HI COOL
DIAGNOSTIC
STATUS
FLASHES
LED
ON
NORMAL OPERATION
NO POWER OR
OFF
INTERNAL CONTROL
FAULT
1 FLASH
IGNITION FAILURE
2 FLASHES
PRESSURE SWITCH OPEN
PRESSURE SWITCH CLOSED
3 FLASHES
WITHOUT INDUCER ON
4 FLASHES
OPEN LIMIT SWITCH
RED
FALSE FLAME DETECTED
5 FLASHES
COMPR. SHORT CYCLE DELAY
6 FLASHES
LIMIT OPEN 5 TIMES IN SAME
7 FLASHES
CALL FOR HEAT
IDT/ODT OPEN
8 FLASHES
9 FLASHES
PSW/LOC OPEN
OFF
NO FLAME PRESENT
ON
NORMAL FLAME PRESENT
AMBER
LOW FLAME SIGNAL
1 FLASH
2 FLASHES
FALSE FLAME DETECTED
JUNCTION
EQUIPMENT GROUND
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
FIELD GROUND
PLUG CONNECTION
SWITCH (PRESS.)
FIELD SPLICE
OVERCURRENT
PROT. DEVICE
L2
T2
CC
RCCF
C
F
L2
L2
L2
3
L2
SEE NOTE 2
TR
GV
M
H
MVC
C
CC
T1
EM C
T4
CHECK
-
CHECK INPUT POWER
CHECK FUSE(S)
REPLA CE CONTR O L
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
CHECK AUXILIARY LIMIT SW.
CHECK ROLLOUT LIMIT SW.
CHECK PRESSURE SWITCH
CHECK TUBING
CHECK VENT MOTOR
CHECK PRESSURE SWITCH
CHECK WIRING FOR SHORTS
CHECK MAIN LIMIT SWITCH
CHECK GAS VALVE
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
3 MIN COMP. SHORT
CYCLE DELAY
CHECK MAIN LIMIT SWITCH
CHECK AUXILIARY LIMIT SW.
CHECK JUMPER BETWEEN 1
AND 4 ON 6-CIRCUIT
CONNECTOR
CHECK REFRIGERANT
SWITCHES FOR LOSS OF
CHARGE OR HIGH HEAD
PRESSURE
-
-
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
CHECK GAS VALVE
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
SWITCH (TEMP)
IGNITER

Advertisement

Table of Contents
loading

This manual is also suitable for:

M series

Table of Contents