Aqua Simpool pH Instruction Manual

Aqua Simpool pH Instruction Manual

Proportional dosing pump and controller, for dosing chlorine or other liquid disinfectants for private pools

Advertisement

Simpool Modello pH
Pompa peristaltica digitale programmabile
ITALIANO
Manuale istruzioni
ENGLISH
Instruction manual
FRANÇAIS
Mode d'emploi
ESPAÑOL
Manual de instrucciones
DEUTSCH
Bedienungsanleitung
TÜRKÇE
Kullanım kılavuzu
PORTUGUÊS
Manual de instruções
РУССКИЙ
Руководство с инструкциями
ADSP7000407
Simpool
Modello pH
For other languages please visit
http://aqua.quickris.com/simpool-ph/
rev. 1.2
MANUALE ISTRUZIONE e MANUTENZIONE
27/03/2015
ITALIANO
pagina
2
page
41
page
80
página
119
Seite
158
sayfa
197
página
236
Страница 275
1/313

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Simpool pH and is the answer not in the manual?

Questions and answers

Summary of Contents for Aqua Simpool pH

  • Page 1 Simpool Modello pH MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO Simpool Modello pH For other languages please visit http://aqua.quickris.com/simpool-ph/ ITALIANO Manuale istruzioni pagina ENGLISH Instruction manual page FRANÇAIS Mode d’emploi page ESPAÑOL Manual de instrucciones página DEUTSCH Bedienungsanleitung Seite TÜRKÇE...
  • Page 2: Table Of Contents

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH CONTENTS INTRODUCTION ……………………………………….…………………………………………………………………………..……………… Warnings …..…………………………………………………………………...………………………………....………………….. 42 Normative references……… .…………………………………………………………………………..…………………………….…… Technical features ………….……………………………………………………………………………………….…..……………… 1.3.1 Electrical features ……………………………….……………………………………………….……………..…………………… 1.3.2 Performance …………….……………………….……………………………………………….…………………………………. 43 INSTALLATION ………………………………………………………………………………………………….………………………………… General rules ….………. …………………………………….………………………….…………………………………..….……………. 43 Installation kit…...…..……………………………………………………….……………………..…………………………………………...
  • Page 3: Introduction

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 1.0 INTRODUCTION The range of “Simpool” programmable digital peristaltic pumps is designed to manage swimming pools and consists of the following models:  pH model: for dosage proportional to the pH value ...
  • Page 4: Technical Features

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 1.3 TECHNICAL FEATURES 1.3.1 ELECTRICAL FEATURES For the power supply value we recommend reading the label on the pump! 1.3.2 PERFORMANCE  Maximum height of the suction tube: 1.5 m ...
  • Page 5: Assembly

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH The full kit supplied is reported in Figure 1 Fig. 1- Installation kit 2.3 ASSEMBLY We always recommend wearing protective masks, gloves, goggles and any other PPE during all installation steps and when handling chemical products.
  • Page 6: Assembly Of The Accessories

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 2.3.1 ASSEMBLY OF THE ACCESSORIES  The probe-holder is installed on a D50 or D63 diameter tube on which a 24 mm diameter hole has been carried out;...
  • Page 7: Electrical Connections

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Fig. 3- Mounting the probe in the probe-holder Installing a long electrode (120 mm) It is possible to use a standard electrode (12x120 mm). In this case it is necessary to use all the parts supplied;...
  • Page 8: Pt100 Temperature Reading Probe

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Connect the pump cable to a voltage that is compatible with the one on the label. For the connections refer to Fig. 5. CAUTION !!!!! Verify that the earth system is perfectly functional and complies with the applicable regulations.
  • Page 9: Hydraulic Connections

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 2.5 HYDRAULIC CONNECTIONS  Make sure the suction tube is placed in the product's container and then connected to the pump's intake fitting (marked with the ▲ symbol on the cover) and tightened with the correct ring nut.
  • Page 10: Programming

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 3.0 PROGRAMMING 3.1 MAIN FEATURES . 9 - U NTERFACE The Increase/Decrease keys allow to change the numerical values and scroll through the lists of options for all the available menu entries.
  • Page 11 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Fig. 10 - Acid and alkaline operating diagrams The pH cycle period features a Ton time during which the pump is active and a Toff time during which the pump is stationary.
  • Page 12 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH MENU When the pump is turned on, regardless of the status of the switch, for a second the display shows the firmware version with the following format “rx.y”. It then displays the first entry of the Initial Menu.
  • Page 13: Quick Start-Up

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH User Menu The User Menu allows to set the main pump dosing parameters. You can browse through the User Menu with the F key and display:  PrI: allows to prime the pump without using the switch. You can start or stop the priming with the Enter key.
  • Page 14: Advanced Programming

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH  A.PH activation value and r.PH deactivation value of the OFA alarm, respectively equal to 0.05 pH and 0.2 pH (see OFA alarm); USER MENU Fig. 11 - Standard programming from User Menu The temperature value can be changed only if the Manual mode is set and the corresponding On-line change is enabled.
  • Page 15: Calibrating The Ph Probe

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Fig. 13- Setting the dosage parameters from the Programming Menu 3.3.3 C ALIBRATING THE P ROBE From the CAL entry you can calibrate the pH's electrode. Before you start, first of all you must get the accessories required to calibrate the probe (Installation kit): ...
  • Page 16: Setting The Temperature

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Fig. 14- pH Probe Calibration Menu 3.3.4 S ETTING THE EMPERATURE The temperature setting allows to correct the pH value read. From the Programming Menu, by accessing it from the °C entry you can choose between the “noA” manual setting and the ”Aut”...
  • Page 17: Displaying And Resetting Statistics

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 3.3.5 D ISPLAYING AND ESETTING TATISTICS From the StA entry on the Programming Menu you can access the Pump statistics submenu. Here below are the parameters saved during the pump's operation: ...
  • Page 18: Pump Calibration

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Fig. 17- pH Pump Calibration Menu 3.3.7 R ESETTING EFAULT ARAMETERS From the r.d.P entry you will be able to reset the equipment's default parameters (refer to the Default Parameters Table in Annex E).
  • Page 19: Resetting Default Parameters

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH  Select the P.P.b value of the pH Proportional Band: to enter and exit the submenu use Enter, to scroll through the 0.5/ 1/ 1.5/ 3 values use the ▲ and ▼ keys;...
  • Page 20: Alarms

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH  Choose if you want to modify the OFA alarm's time frame from the User Menu, OnA: to enter and exit the submenu use Enter, to scroll through “YES/no” use the ▲ and ▼ keys;...
  • Page 21: Off Status Alarm

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 4.3 OFF STATUS ALARM If the switch is left on the OFF position, after 20 minutes the switch alarm is activated and signalled by the pump in the following way: ...
  • Page 22: Temperature Alarm

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH 4.7 TEMPERATURE ALARM The Temperature Alarm is activated whenever the temperature mode (°C) in the Programming Menu is set to automatic “Aut”, but the PT100 probe is not connected (temperature value reported as t - -.
  • Page 23 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Removing the peristaltic tube Step 1 - Open the front glass Step 2- Turn the roller clockwise and release the (left) intake ring nut Step 3 - Removing the tube Step 4 - Release t the (right) delivery ring nut and remove it completely Fig.
  • Page 24: Troubleshooting

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Placing back the peristaltic tube Step 1 - Position the tube and secure it on the left-hand side Step 2 - Insert it in the bell by turning the roller Step 3 - Close the front glass Fig.
  • Page 25: Returning Material To The After-Sales Service

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Problem: liquid leaking from the peristaltic tube Solution: 3. Make sure the delivery and intake tubes are inserted properly and the ring nuts are well tightened. 4. Check the status of the peristaltic tube. If evident malformations are detected, make sure that the material is compatible with the product being dosed by consulting the chemical compatibility table (see ANNEX D), and then go ahead with the replacement.
  • Page 26: Annexes

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX A - Overall dimensions ADSP7000407 rev. 1.2 27/03/2015 65/313...
  • Page 27: Annex B - Reference Figures

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX B - Reference Figures Ref. Description Two-coloured LED 3-digit display with 7 segments Roll-holder Peristaltic tube Intake fitting Delivery fitting Electronic Board layout Ref. Description Equipment Power Supply Connector...
  • Page 28: Annex C - Exploded Views

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX C - Exploded views ADSP7000407 rev. 1.2 27/03/2015 67/313...
  • Page 29 ADSP8000029 KNOB TO SECURE CLEAR TEC COVER ADSP4100207 SKF 618/6 100L ECOWASH PUMP ADSP7000577 SIMPOOL – AQUA PERISTALSTIC POLYCARBONATE LABEL ADSP7000484 SIMPOOL pH PVC LABEL ADSP6000714 STAINLESS STEEL A2 M 2.9 X 13 SCREW UNI 6954 (slotted pan head) ADSP9600001...
  • Page 30: Annex D - Chemical Compatibility Table

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX D - Chemical Compatibility Table Key: 1: excellent/good resistance 2: moderate resistance 3: non-resistant EPDM Product Formula Ceram. PVDF PP PVC Hastel. PTFE NBR PE (Viton) (Dutral)
  • Page 31 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Key: 1: excellent/good resistance 2: moderate resistance 3: non-resistant Product Formula PharMed Tygon LFL Santoprene Acetic acid 50%- 60% CH3COOH Hydrochloric acid 37% Hydrofluoric Acid 40-48% H2F2 Phosphoric acid...
  • Page 32: Annex E - Default Parameters

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX E - Default Parameters Default Parameters Table Parameter IT Parameter EN Meaning Value A.bu b.En Buzzer Enabling Inhibiting Signal A.In In.E enabling OFA Alarm Activation A.PH A.PH 0.05 pH...
  • Page 33: Annex F- Acronyms Table

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX F- Acronyms Table Acronym IT Acronym EN Meaning A.bu b.En Buzzer Enabling A.In In.E Inhibiting Signal Enabling ACI/ ALC ACI/ AL.d Acid/Alkaline Priming OFA Alarm Activation (minimum variation) in the Settings Menu A.PH...
  • Page 34 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH St.P P.St Pump Stop (due to Level Alarm) t.F.P P.d.t Pump Operating Time tr.P P.CA Pump Calibration °C °C Temperature in °C ADSP7000407 rev. 1.2 27/03/2015 73/313...
  • Page 35: Annex G - Menu Layouts

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX G - Menu Layouts Initial Menu User Menu ADSP7000407 rev. 1.2 27/03/2015 74/313...
  • Page 36 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Probe Calibration Menu Programming Menu ADSP7000407 rev. 1.2 27/03/2015 75/313...
  • Page 37 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Statistics Menu Settings Menu ADSP7000407 rev. 1.2 27/03/2015 76/313...
  • Page 38: Annex Hpool Parameters Balance

    Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ANNEX H – POOL PARAMETERS BALANCE The Taylor balance diagram is a practical tool to keep the pool's water well-balanced: you can control an outdoor residential pool by monitoring the pH, the TH (or Total Hardness) and the CAT (or Complete Alkalimetric Title).
  • Page 39 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Taylor's Water Diagram ADSP7000407 rev. 1.2 27/03/2015 78/313...
  • Page 40 Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH Pursuant to art. 13 of Leg. Decree no. 151 dated 25/07/2005 (implementation of Directives 2011/65/UE , 2002/96/EC, 2003/108/EC) it is notified that: The electric and electronic devices must not be considered as household waste.

Table of Contents