Monitor Modem Performance - Canoga Perkins 2345 User Manual

T3 fiber optic modem
Table of Contents

Advertisement

One screen shows G.826 statistics.
Errored Blocks:
Blocks of data with one or more bit errors
Errored Seconds:
Number of one-second periods with any errored blocks; includes all Sev Errored Sec
Sev Errored Secs: Severely Errored Seconds
Number of one-second periods with 30% or more errored blocks
Bgd Blk Errors: Background Block Errors
Number of errored blocks that were not within a Sev Errored Sec
Errored Sec Ratio: Errored Seconds Ratio
Percentage of total seconds that were errored seconds; includes all Sev Errored Sec
Sev Err Sec Ratio: Severely Errored Seconds Ratio
Percentage of total seconds that were severely errored blocks
Bgd Blk Err Ratio: Background Block Error Ratio
Percentage of total seconds that contained errored blocks that were not within a Sev
Errored Sec
To view the transmission statistics, follow these steps:
1. At the Main Menu, type
2. At the Performance Monitoring screen, press <Space> to cycle through the Current, 24 Hour, and
G.826 Statistics. To reset all counters, press <Tab>.
3. To return to the Main Menu, press <Esc>.

Monitor Modem Performance

The 2345 provides one screen that monitors both local and remote modems for these errors:
Composite LOS Errors: Shows loss of signal if running in unframed mode; if running in framed
mode, check SQL Rxx
Electrical LOS Errors: Shows loss of signal if running in unframed mode or shows loss of synch
if running in framed mode
Electrical Yellow Errors: Loss of frame received
Electrical Blue Errors: Alarm Indication Signal (AIS) received
Electrical Red Errors: Loss of frame error
SQL Rx1 and Rx2 Errors: Signal error generated by the optics; use this when running in
unframed mode
Optical Xmit Errors: Faulty optical signal transmitted by this modem
To view the modem performance, follow these steps:
1. At the Main Menu, type
2. At the Link Error Counters screen, press <Tab> to reset all counters, press <Tab>.
3. To return to the Main Menu, press <Esc>.
3-14
EdgeAccess Universal Chassis System
, "Performance Monitoring," and press <Enter>.
3
, "Link Error Counters," and press <Enter>.
4
Model 2345 User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents