Service Manual MT1190C 19” Color Television THIS SERVICE MANUAL IS FOR MT1190C SUFFIX A , B , C, D AND E CRT USAGE SUFFIX A SUFFIX B SUFFIX C SUFFIX D SUFFIX E V451 5721- 015ST51N 5721- 51CN020T 5721-028TT48N 5721- 029NT48N...
FEATURES On-screen graphics guide you through setup features and operations Automatic programming of channels allows easy selection of stations available in your viewing area Sleep timer programs the TV to turn itself off at a preset time One day timer programs the TV to come on once at a preset time Weekly timer programs the TV to come on at a preset time every day 26 button infrared remote control allows remote operation VHF/UHF/CATV tuning allows reception of standard broadcasts or cable TV channels...
IMPORTANT SERVICE SAFETY INFORMATION Operation of receiver outside of cabinet or with back removed involves PROTECT YOUR CUSTOMER a shock hazard. Work on these models should only be performed by 1. Inspect all lead dress to make certain that leads are not pinched those who are thoroughly familiar with precautions necessary when or that hardware is not lodged between the chassis and other working on high voltage equipment.
( ADJUSTMENT BY REMOTE CONTROL ) ADJUSTMENT MODE The following adjustment items can be performed from menus by Remote Control as shown below : NOTE: The button combination and position on the Remote Control to select the adjustment items is given on page 4. 1.
REMOTE CONTROL LAYOUT VIDEO VIDEO VIDEO METHOD OF RECALL V-BLOCK PASS NUMBER If user forgets the V-Block Pass Number, call recall by the Service Remote Control or User Remote Control. 1. If use the Service Remote Control, at the Pass Number entry menu, while holding down [SHIFT] button and press the [Q.REV] button repeatedly four times.
INSTALLATION AND SERVICE INSTRUCTION CAUTION: Use an isolation transformer when performing any service on this chassis. SHUTDOWN CIRCUIT: When the high voltage rises, there are simultaneous voltage increase developed at termi- nal 5 of the Horizontal Output Transformer (T671) and applied to pin 29 of IC301. If excessive high voltage is produced, the increased voltage developed exceeds the rating of zener diode D552 causing the Horizontal Oscil- lator to stop functioning and the high voltage system to shut down.
SOUND IF ADJUSTMENT Connect TV Test Pattern Generator (NTSC signal, 70dB u, channel 2) to EXT. Antenna Terminal (TE1) through TV Channel Signal Generator. (Standard modulation is 400Hz at 25kHz deviation for sound signal. Connect positive lead of DC Digital Voltmeter to TP7 and negative lead to TP4. Adjust T203 so that the DC Digital Voltmeter reading is 4.0V.
Page 9
STATIC CONVERGENCE ADJUSTMENT (Refer to Fig. 3 and 4) IMPORTANT: Before proceeding, make sure the location of the convergence magnet assembly on the neck of the CRT is as shown in Fig. 3. The rear edge of this assembly must be positioned 65 mm from the tip of the CRT base. If not properly positioned, convergence adjustment may be difficult, if not impossible.
GREEN GREEN WEDGE B BLUE BLUE GREEN BLUE WEDGE C GREEN BLUE WEDGE A BLUE GREEN WEDGE A DEFLECTION YOKE REAR VIEW DEFLECTION YOKE REAR VIEW BLUE GREEN GREEN GREEN WEDGE B WEDGE B BLUE BLUE BLUE GREEN WEDGE C BLUE GREEN GREEN...
Page 11
HORIZONTAL PHASE ADJUSTMENT Connect TV Test pattern Generator (NTSC signal 70dB u, Monoscope Pattern) to EXT. Antenna Terminal (TE1) through TV Channel Generator. (NOTE: For steps 2, 3 and 4 below, refer to page 3 for Adjustment By Remote Control Method). Go to Adjustment Mode (2) by remote control.
Page 12
VIDEO IN ADJUSTMENT Connect Pattern Generator (1Vp-p, Color Bar Pattern) to video jack (J701). Connect positive lead of Oscilloscope probe 1 to R703 and negative lead of Oscilloscope to TP4 to detect video in signal. Connect positive lead of Oscilloscope probe 2 to TP10 and negative lead of Oscilloscope to TP4. Select Video Mode by remote control.
VOLTAGE CHART (all in volts) OPERATION CONDITION: TINT, BRIGHT and COLOR CONTROL ......CENTER CONTRAST ..............MAXIMUM COLOR BAR SIGNAL IC101 TERMINAL No Volt TERMINAL No Volt TERMINAL No Volt TERMINAL No Volt TERMINAL No Volt IC102 TERMINAL No Volt IC301 TERMINAL No Volt...
Page 15
CHASSIS WAVEFORM WF-1 1.0Vp-p(H) WF-2 9.7Vp-p(H) WF-3 50.0Vp-p(V) WF-4 2.4Vp-p(V) WF-5 27.4Vp-p(H) WF-6 21.0Vp-p(H) WF-7 27.0Vp-p(V) WF-8 195.0Vp-p(H) WF-9 0.75Vp-p(H) NOTES: WAVEFORMS SHOWN WERE PRODUCED USING A PATTERN GENERETOR WITH ITS CONTROL SET TO PRODUCE A COLOR BAR SIGNAL AND A WIDEBAND OSCILLOSCOPE WITH LOW CAPACITY PROBE TO PREVENT LOADING.
Ref No. Part No. Description Ref No. Part No. Description GENERAL UNIT PARTS LIST MISCELLANEOUS 1532-26001 Window DY501 4993-119 Coil Deflection Yoke SUFFIX D 1662-79801 Push Button DY501 4993-123 Coil Deflection Yoke SUFFIX E 2132-412 Wedge Deflection Yoke;SPACER(x3) LCN801 4163-06038003 Connector with Lead Wire;(SP) 2133-334 Protector;BUTTON...