Download Print this page

Operation; Problem Solving - Samlexpower VTC605-12-12 Owner's Manual

Vtc605 series dc to dc step up converter

Advertisement

Turn the power switch on the front of the unit on to energize the outputs.
To adjust the output voltage, turn off the power switch. Remove the plate from the top of the box.
Reach in with a non-conductive device such as a pencil and open or close the dip switches as
shown below to select the desired output voltage. Replace the plate. Turn the power switch on.
MINIMUM
+0.5V
If the load exceeds the continuous rating for too long a period, the internal temperature sensor
will cause the unit to stop boosting the input voltage until the unit has cooled down. After the
unit has cooled down, normal operation will resume.
If the input voltage drops below the specified minimum input, the unit will sound the alarm.
If the output voltage drops below the specified minimum, the unit will sound the alarm.
If the current demanded by the devices connected to the unit exceed the maximum current
rating, the fuse will blow.
If the fuse blows with no load connected, check that the power leads are connected to the
battery with the correct polarity; if they are then the unit is damaged and must be returned for
repair.

OPERATION

+1.0V
+1.5V
BLACK PORTION INDICATES SWITCH IS PUSHED DOWN

PROBLEM SOLVING

+2.0V
+2.5V
+3.0V
+3.5V

Advertisement

loading

This manual is also suitable for:

Vtc605-12-24