EXCELL PRECISION CO., LTD
Read weight comparison setting value RS
: Groups(00 ~ 09) : Setting Items
Show "HI" presetting value
HI
Show "LO" presetting value
LO
Note : (Group) is various depended on different models
00 The first group
01 The second group
02 The third group
EX:
RS02LO<CR><LF>
ANS:
RS02LOXXXXXX<CR><LF>
Command Format C
Host
Command+ Data
Slave
Write weight comparison setting value WSXXXXXX
: Groups(00 ~ 09) : Setting Items XXXXXX: Setting Value
Write "HI" setting value
HI
Write "LO" setting value
LO
Note : (Group) is various depended on different models
00 The first group
01 The second group
02 The third group
EX:
WS00HI001000<CR><LF>
ANS:
WS00HI001000<CR><LF>
Command Format D
Host
Data
Slave
Value (e.g. Price)
1
2
3
When the Slave receives this data format, it will transfer the data and display it on its LCD.
The function is effective when the weight value is over 0.
The above 4 (ABCD) command formats are RS232 bi-directional. There are the
following error messages received by Slave terminal (scale).
Error messages:
E1: Wrong command
E2: Command format error (Wrong parameters)
E3: Command not recognised
02005159
Position of decimal point
4
5
6
Show "LO" presetting value
Command+ Data
Write "HI" setting value
CR
1
˙
40
LF
ZSME300000225