6. INTERFACES

Rev01, Issue01
Ji8
Ji7
Ji5
Ji6
LEDS
PD2
PD1
D1
Note : On the SMT380-02 PCB the TIM-site is
rotated through 180 Degrees

Fig. 2 : Physical Layout of the SMT340/360/380

Fig. 2 Shows the Physical Layout of the SMT340/360/380, indicating the external connectors with their
location and numbering. Connector definitions are as follows:
Ji1
: External clock input via 50ohm CV10 coax connector.
Ji2
: External clock input via 50ohm MMBX coax connector.
Ji3
: External enable/trigger input via 50ohm CV10 coax connector.
Ji4
: External enable/trigger input via 50ohm MMBX coax connector.
Ji5
: Channel A analogue input via 50ohm CV10 coax connector.
Ji6
: Channel A analogue input via 50ohm MMBX coax connector.
Ji7
: Channel B analogue input via 50ohm CV10 coax connector.
Ji8
: Channel B analogue input via 50ohm MMBX coax connector.
Document Name:
SMT340_360_380_User_Manual_Rev01_Iss01.doc
Document Number:
TBD
Author:
PC Pelser / MR Vogel
Document Title:
SMT340/360/380 User Manual
Shielded ADCs
Ji3
Ji4
Ji1
Ji2
Preliminary
S2
LEDS
S1
SMT340_60_80_PCB_Layout_Rev01_Iss01.vsd
Revision:
01
Original Date:
25 June 2001
Revision Date:
25 June 2001