F R A M E D
The illustrations below provide installation
specifications for Model ICBCT15I/S.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 1 5 I / S
381 mm
OVERALL WIDTH
89 mm
TERMINAL BOX
Overall Dimensions
M O D E L I C B C T 1 5 I / S
Overall Width
Overall Height
Overall Depth
Minimum Cabinet Depth
Minimum Height Clearance* 114 mm
Cut-Out Width
Cut-Out Depth
*Minimum 152 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to ± 3 mm.
8
I N D U C T I O N C O O K TO P S
M O D E L I C B C T 1 5 I / S
533 mm
OVERALL
DEPTH
330 mm
51**
mm
114 mm
381 mm
89 mm
533 mm
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm
recommended cabinet width for installation of single 381 mm cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
578 mm
to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 457 mm above countertop.
340 mm
Countertop Cut-Out
489 mm
max
457
mm
489 mm
COOKTOP CUT-OUT
64 mm
min
DEPTH
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
If Model ICBCT15I/S is installed above
cabinets, the electrical placement is not critical.
The appliance shall be installed in such a way
to allow disconnection of the appliance from
the supply mains after installation.
838 mm
RECOMMENDED
CABINET WIDTH
51 mm*
min
340 mm
CUT-OUT TO
COMBUSTIBLE
COOKTOP CUT-OUT
MATERIALS
WIDTH
(BOTH SIDES)
114 mm
E
381
mm
381 mm
340 mm
COOKTOP CUT-OUT
WIDTH
64 mm
CUT-OUT DEPTH
min
FRONT OF COUNTERTOP
762 mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP