Manual
Gas Detector PCE-FHM 10
Version 1.0
Date of creation: 15.12.2015
Date of last change: 12.05.2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCE-FHM 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PCE Instruments PCE-FHM 10

  • Page 1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0 Fax: (561) 320-9176 Fax: (0) 2380 98703 9 info@pce-americas.com info@pce-instruments.com www.pce-instruments.com/english www.pce-instruments.com Manual Gas Detector PCE-FHM 10 Version 1.0 Date of creation: 15.12.2015 Date of last change: 12.05.2016...
  • Page 2: Table Of Contents

    Setting up the PC software ......................9 5.7.2 Data logger settings ........................13 5.7.3 Software functions........................15 5.7.4 Import the data to Excel ....................... 16 Disposal ......................... 17 Contact ........................17 PCE Instruments UK ........................ 17 PCE Americas .......................... 17...
  • Page 3 Manual...
  • Page 4: Introduction

    Please, read this manual carefully and completely before you use the device for the first time. The device may only be used by thoroughly qualified personnel and repaired by PCE Instruments personnel. This user’s handbook is published by PCE Instruments without any guarantee.
  • Page 5: Specifications

    <±2 % Silicone hose 30 mm Delivery 1 x formaldehyde data logger PCE-FHM 10 with a probe 6 x 1.5 V AAA batteries 1 x flexible tube (30 cm) 1 x USB cable for data transfer 1 x CD with PC Software...
  • Page 6: System Description

    If you want to use the data logger functions of the PCE-FHM 10, in certain circumstances you may need a power supply to provide the unit with electricity for an extended period of time. For that you may...
  • Page 7: Automatic Shutdown

    Manual Automatic shutdown The meter turns off automatically after 15 minutes, if you have not touched any button during this time. To deactivate this setting, press PWR and HOLD when the device is off. A sign "n" appears on the screen. After that you can then continue normal operation.
  • Page 8: Alarm And Beeper Functions

    Manual Alarm and beeper functions The default alarm threshold is 0.08 HCHO for different applications. Press and hold the SET button to adjust a threshold value / -alarm. With the buttons MODE and MAX / MIN you can navigate between the individual digits of the alarm value.
  • Page 9: Calibration Settings

    Manual 5.6.1 Calibration settings If desired, the default calibration time of 15 seconds, and the standard for calibration value for gas can be changed. This feature is designed for experienced users and for professional use only. Please follow the steps as mentioned: 1.
  • Page 10 Manual In order to be able to connect the device to a PC, you must first install the USB driver. To do this, follow these steps: 1. Insert the included CD into your CD-ROM drive. 2. Run the file PL2303_Prolific_DriverInstaller_v110.exe file in the folder "Step1 - USB Driver". 3.
  • Page 11 Manual...
  • Page 12 Manual In this case, proceed as follows: 1. Check if the device is connected to the PC. 2. Check if the USB driver is installed properly. To do this, open the Control Panel and then the Device Manager. If you see this, the device is properly installed: 3.
  • Page 13: Data Logger Settings

    Manual 5.7.2 Data logger settings Click “Setting" and then "Log Setting" in the menu bar of the software to get to the data logger settings. There are 3 different tabs in which you can configure settings Logger's ID Here you can change the name of the instrument. To do this, enter the desired name and click Ok.
  • Page 14 Manual Rate (h: m: s) Here you can set the time interval at which the data logger saves the measured values. Values between 1 second and 6 hours are possible. Start mode Here you can choose between 5 different logger modes.
  • Page 15: Software Functions

    Manual 5.7.3 Software functions Overview Selected measuring Logger Date and point status time HCHO Temperature/ concentration humidity Download button Temperature, humidity and HCHO value of the selected measuring point Time of the measurement Zoom in and out and change the colors Zoom In: Hold Ctrl and press the left mouse button to zoom in the graph view.
  • Page 16: Import The Data To Excel

    Manual Open File To open a file, proceed as follows: 1. Click "File" and then "Open File" in the menu bar. 2. Select the desired file and open it by clicking OK. Save File To save a recording as a file, proceed as follows: 1.
  • Page 17: Disposal

    In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. If you have any questions, please contact PCE Instruments. Contact If you have any questions about our range of products or measuring instruments please contact PCE Instruments.