Ravenheat CS 80 Instructions For Use Installation And Servicing

Ravenheat CS 80 Instructions For Use Installation And Servicing

High efficiency condensing combination boiler

Advertisement

Instructions for Use
Installation and Servicing
To be left with the user
HIGH EFFICIENCY
CONDENSING
COMBINATION BOILER
CS 80 (T)
Natural Gas (G20) II
LPG (G31) II
G.C. No. 4758147
2H3P
CS 90 (T)
Natural Gas (G20) II
LPG (G31) II
G.C. No. 4758149
2H3P
Technical and illustrative data are not binding and can be modifi ed without prior notice.
The descriptions and illustrations in the present booklet are for guidance purposes only.
Website: www.ravenheat.co.uk - E-mail: sales@ravenheat.co.uk
G. C. No. 4758146
2H3P
G. C. No. 4758148
2H3P
RAVENHEAT MANUFACTURING LTD
CHARTISTS WAY, MORLEY, LEEDS, U.K. LS27 9ET
TEL.: 0113 252 7007
1312
-
FAX: 0113 238 0229

Advertisement

Table of Contents
loading

Summary of Contents for Ravenheat CS 80

  • Page 1 Technical and illustrative data are not binding and can be modifi ed without prior notice. The descriptions and illustrations in the present booklet are for guidance purposes only. RAVENHEAT MANUFACTURING LTD CHARTISTS WAY, MORLEY, LEEDS, U.K. LS27 9ET TEL.: 0113 252 7007 FAX: 0113 238 0229 Website: www.ravenheat.co.uk - E-mail: sales@ravenheat.co.uk...
  • Page 2: Clearances Around The Appliance

    Your Ravenheat Condensing Low Nox combination boiler system, between 1 and 1.5 bar to allow the boiler to system, between 1 and 1.5 bar to allow the boiler to has been designed to supply your Central Heating and operate.
  • Page 3: Appliance Status Indicators

    1.4 APPLIANCE STATUS INDICATORS During the initial charge time, the display doesn’t Your boiler is equipped with a large LCD display allow the visualisation and/or modifi cation function that indicates the appliance operating status parameters. Instead other functions are working. (fi...
  • Page 4: Digital Display

    1.5 DIGITAL DISPLAY 1 - Day indicator: Fig. 2 (time clock version only) 1. Monday 1. Monday 2. Tuesday 2. Tuesday 3. Wednesday 3. Wednesday 4. Thursday 4. Thursday 5. Friday 5. Friday 6. Saturday 6. Saturday 7. Sunday 7. Sunday 2 - Time (time clock version only).
  • Page 5: Programming The Heating Times

    PROGRAMMING THE HEATING TIMES (time clock vers time clock version only) The appliance incorporates a digital clock Once the times are set, press the P button and programmed with a default heating pattern this will return to the main screen. (see table 1);...
  • Page 6 2.0 GENERAL LAYOUT (Fig. 3) Fig. 3 1 - Condensate trap 12-Water pressure transducer 23 - Spark igniter 2 - Gas valve 13 - CH return 24 - Fan 3 - Gas inlet 14 - Control board 25 - Burner 4 - Drain point 15 - Circulation pump 26 - Manual air vent...
  • Page 7 2.1 OPERATING SCHEME (Fig. 4) Fig. 4 1 - Flue exhaust manifold 10 - Burner 19 - Safety pressure relief valve 2 - Condensate drain 11 - Spark electrode 20 - Diverter valve motor 3 - CH return 12 - Sensor electrode 21 - Plate heat exchanger 4 - CH return sensor 13 - Fan...
  • Page 8: General Function

    INTRODUCTION As the heating sensor reaches temperature This boiler is designed for the production of the fan speed modulates to maintain the central heating and domestic hot water combined in one unit. temperature set on the display panel. It is fi tted with an automatic domestic hot When starting, the fan will always start at the set-point speed.
  • Page 9: Safety Device

    When a hot water tap is turned on the diverter When a hot water tap is turned on the diverter This also takes place when in winter mode, valve motor moves to exclude the central valve motor moves to exclude the central if there is no demand for heat to the central heating circuit, the boiler automatically heating circuit, the boiler automatically...