How to Enter the Service Mode
About Optical Sensors
Caution:
An optical sensor system is used for the Tape Start
and End Sensors on this equipment. Carefully read
and follow the instructions below. Otherwise the unit
may operate erratically.
What to do for preparation
Insert a tape into the Deck Mechanism Assembly and
press the PLAY button. The tape will be loaded into
the Deck Mechanism Assembly. Make sure the power
is on, TP507 (SENSOR INHIBITION) to GND. This will
stop the function of Tape Start Sensor, Tape End Sen-
sor and Reel Sensors. (If these TPs are connected
before plugging in the unit, the function of the sensors
will stay valid.) See Fig. 1.
Note: Because the Tape End Sensors are inactive, do
not run a tape all the way to the start or the end of the
tape to avoid tape damage.

PREPARATION FOR SERVICING

About REC-Safety Switch
Caution:
The REC-Safety Switch is directly mounted on the
Main CBA. When the Deck Mechanism Assembly is
removed from the Main CBA for servicing, this switch
does not work automatically.
What to do for preparation
In order to record, press the Rec button while pushing
REC-SAFETY SW on the Main CBA. See Fig. 1.
Q503
SW506
(REC-SAFETY SW)
1-4-1
Q504
TP507
S-INH
Fig. 1