TROUBLE SHOOTING
4-1-1) Test Function (Forced Operation / Forced Defrost)
●
RSG5K/F/D***, RSG257AA**
Press the Power Freeze and the Fridge buttons for more than 8 seconds at the same time.Then, the
Freezer & Fridge temperature display will be turned off and the Test mode begins.
RSG5BL**
Press the Freezer temp and the Child Lock buttons for 6 seconds at the same time and then Panel
display blinks for 4 seconds at an intervals of 0.5 sec. During this time, press the Child Lock Button and
then panel display will be off and Test mode begins.
●
With the Inverter Comp model, when you press the Test button (Power Freeze, Lighting, Freezer,
Fridge KEY), the Test function will be selected in the following order.
Forced Operation 1 (FF 1)
Forced Fridge/Freezer Defrost (Fd)
●
The recommended way to cancel the Test function is turning off an on the unit.
RSG5B*
Press the Freezer temp and the Child Lock buttons for 6 seconds at the same time.
RSG5K/F/D*
RSG257*
Press the Power Freeze and the Fridge buttons for 8 seconds at the same time.
Forced Operation 2 (FF 2)
Cancelled (Normal Operation)
48
Forced Operation 3 (FF 3)