Optional Accessories; Boost Ventilation Switch; Co Sensor; Remote Control - jablotron Futura User Manual

Heat recovery unit
Hide thumbs Also See for Futura:
Table of Contents

Advertisement

You can rotate the switch to change the operation mode of the heat recovery unit (see page 7, 5. Operation Modes) in the
sequence:
Constant Power 1 - 2 - 3 - 4 - 5
Automatic Mode
Fig. 8 – Changing the operation mode
Turning of the switch will terminate the Boost, Night Mode, Party and Circulation functions. Turning does not have any
impact on the Holiday function.
When a certain function of the heat recovery unit has been activated, you can activate another function that will deacti-
vate or interrupt the previous function, or the functions can run simultaneously.
The Boost function will interrupt the Circulation function. The Night Mode and Party functions will continue after expiration
of the Boost function. If the Boost function is started and the Holiday function has also been selected (both the symbols
are lit), the Holiday function will continue after expiration of the Boost function.
If the Night Mode function is selected, the Boost and Party functions will be terminated.
If the Holiday function is selected, the Boost, Night Mode and Circulation functions will be terminated.
If the Party function is selected, the Boost, Night Mode and Circulation functions will be terminated. The Party function
cannot be activated if the Holiday function has been activated.

7.1.2. Optional accessories

The heat recovery system can be supplemented with boost ventilation switches, CO
sensors, more wall-mounted controls
2
(max. 3 pieces), VAC material and distribution elements as optional accessories.

7.1.2.1. Boost ventilation switch

The forced ventilation (Boost) mode can be activated with boost ventilation buttons, which are usually installed in rooms
that require quick exhaust of excessive humidity and smells (bathroom, WC and kitchen). The functions of the boost ven-
tilation switch are activated after pressing of the button. One pressing means activation at the top exhaust level for the
selected time. After expiration of the respective time, the system will return to the original ventilation level setting. You
can deactivate the boost function by pressing the button again.
7.1.2.2. CO
sensor
2
The sensors are used for automatic control of the operation of the heat recovery unit. When a selected threshold is ex-
ceeded, the power of the unit will be increased to ventilate the room to an optimum level. The fan speeds automatically
increase or decrease based on the data of the sensors. Max. 8 CO
sensors can be installed on residential premises.
2

7.2. Remote control

The heat recovery system can be controlled remotely through the MyJABLOTRON mobile application for iOS and Android.
This is a unique service that provides online access to the heat recovery system with the possibility of its full control from
anywhere and any time by means of a smart phone or tablet (remote monitoring, administration of all the user functions
and settings, automatic alert to filter replacement and error statuses).