TECHNICAL GUIDE

REMARKS ON DISASSEMBLING AND REASSEMBLING
HANDS
1
How to install
* Match the polarity of the ROTORs for stopwatch and alarm,
and then install the hands.
Check that the voltage of rechargeable battery exceeds 1.2 V
and the watch is working.
*Crown position: normal position.
Short-circuit in touching the AC pattern and the Rechargeable
Battery Clamp with tweezers (refer to the Fig. 1).
In order to match the polarity of the ROTORs, pull out the crown
to the second position, then short-circuit in touching the Pattern
A and the Rechargeable Battery Clamp with tweezers (refer to
the Fig. 2).
Install the Mode indicator hand at "E" position and the Alarm
(hour / minute) hands at "12" position.
Install the Small second hand, the Hour hand, the Minute hand
and the Chronograph second hand at "0" position.
DIAL
2
How to install
Set the notched portions of the dial to the guide posts (4 posts)
of the HOLDING RING FOR DIAL, and check that the dial is fixed
in position.
SPACER FOR SOLAR CELL
3
How to install
Set the notched portions of the SPACER FOR SOLAR CELL to
the guide posts (5 posts) of the HOLDING RING FOR DIAL, and
check that the dial is fixed in position.
10/24
Cal. V195A
Fig. 1
5
pattern A
5
Fig. 2