Download Print this page

Korg DW-8000 Service Manual page 36

Programmable digital waveform synthesizer
Hide thumbs Also See for DW-8000:

Advertisement

8.
ADJUSTMENT PROCEDURES
HELP
KEY *<GRPH
+H)
PROGRAM
NO.
11
12
13
14
15
16
17
18
21
ASSIGN
MODE
POLY
1
POLY1
POLY1
POLY1
POLY1
POLY1
POLY
1
POLY
1
POLY1
PARA.
MEMORY
13
23
31
31
26
72
72
71
73
OSC1
oct
1
i
8
8
8
8
8
8
8
8
8
waveform
i
D
IL.
IS
15
IS
IB
6
IS
IS
15
16
level
13
31
n u
n u
n u
n u
31
31
31
31
A
BEND
si.
13
n
u
n
u
n u
n u
n u
n
u
n u
8
n
u
mode
IS
n
r\
n
/~1
r\
/n
/
1
n
/n
time
IS
n
u
n u
n
u
n u
n
u
n u
n u
u
n
u
in
n
u
n
u
n u
n u
n u
n u
n u
0
n
u
OSC2
oct
D
i
L.
i
8
8
8
8
8
8
8
8
8
waveform
55
15
IE
IS
IB
IB
IS
16
15
15
level
53
n u
31
n u
n
u
n
u
n u
n
u
8
n u
interval
53
l
l
j
f
,
i
<
i
as
n u
n u
n u
n u
n u
n
u
n u
8
n-
u
NOISE
level
55
n u
8
n u
n
u
3!
n u
n u
n
u
n
u
VCF
cutoff
3
i
53
S3
38
33
63
63
63
53
53
resonance
3,3
n u
n u
31
31
n
u
n
u
n
u
8
n
u
kbd
track
33
n u
n u
n u
n u
n
u
n u
n u
n
u
n
u
polarity
33
/"I
r\
n n
/n
n n n
/"I
ee
in*
33
n u
n u
n u
n
u
n
u
n
u
n
u
8
n
u
VCF
attack
3
1
n u
n u
n u
8
n
u
n
u
n
u
8
n
u
decay
35
n u
8
n u
n
u
n
u
n u
n u
n u
8
break.
p
33
n u
n u
n u
n u
n u
n
u
n
u
8
n
u
slope
33
n
u
n
u
n
u
n
u
n
u
n
u
n u
8
n
u
W5
n
u
n
u
n u
n u
n u
n
u
n u
8
8
release
3B
8
n u
n u
n
u
n
u
n u
n u
8
n
u
velocity
31
n
u
8
n u
n u
n u
n u
n u
8
n
u
PROGRAM
NO.
1 1
v
12
13
14
15
16
17
IB
21
ASSIGN
MODE
POLY1
POLY1
POLY
1
POLY1
POLY1
POLY1
POLY1
POLY1
POLY1
PARA.MEMORY
13
23
31
31
26
72
72
71
73
VCA
attack
5!
n u
8
n u
8
n u
8
n u
n
u
8
decay
58
n u
0
n
u
n u
n u
n u
n u
in
iU
18
break,
p
S3
31
31
31
31
31
31
31
n
u
8
slope
S3
n u
D
n
u
n
u
n
u
n u
8
8
n u
sustain
55
31
31
3
1
3!
31
31
31
n u
n u
release
55
n u
D
n u
n
u
n u
8
n u
in
IU
in
iU
velocity
55
n u
0
n u
n
u
n u
n u
n
u
n
u
n u
MG
w.form
51
A
A
A
A
A
A
A
A
A
freq
55
n u
n u
n
u
n u
n
u
n u
n u
n
u
n u
delay
53
n u
u
n u
n
u
n
u
n
u
n u
n u
n u
osc
S3
n u
D
n u
n u
n u
n u
n
u
n u
n u
vcf
55
n u
n u
n u
n u
n u
n u
n u
n u
n u
BEND
osc
55
n
L.I
n u
n u
n
u
n u
n u
n u
n u
n u
vcf
55
off
off
off
off
off
Off
off
off
off
ODL
time
n
l
n u
B
n
u
n u
n u
n u
n u
3
n u
factor
n
d
ii-
n u
D
8
n
u
n u
15
n u
n u
n u
feedback
55
n u
D
n u
n u
8
n
u
n u
IS
IS
frequency
83
n
LJ
D
n
u
n u
n u
n u
n u
n u
n u
55
n u
0
n
u
n u
n u
n
u
n u
n u
n u
effect
lev
55
n u
0
n u
n
u
8
IS
IS
IS
IS
PORTA
time
nn
G
8
n
u
n
u
n u
n u
8
n
u
n u
A.T osc
mg
81
r>
u
n u
n u
8
n u
8
n u
n
u
0
vcf
88
n u 0
n u
n u
n
u
n
u
8'
n u
8
VCfl
83
n u
D
n u
8
n u
8
8
n u
8
Caution:
1)
This
product
has
been throughly
adjusted
at
the factory
before shipment.
Therefore never turn any
Semi
Fixed
VRs
other than those required
for
servicing.
2)
After turning
on
power, wait
at
least
15 minutes
before
beginning
test
and
adjustment.
3)
Be
sure to save the data
on
tape before loading
test
data
as
when
loading
test
data
into
DW-8000,
previous
data
is
erased.
1.
Clearing
RAM
and Loading
Test
Data
1)
After keeping
DW-8000
power on
at
least
15 minutes,
once
turn
off
power and
then
on
pressing
number
keys
[5]
and
[8]
.
2)
Connect
to
an Amplifier
etc.
and confirm
if
there
is
no
sound
to
check
all
data of
RAM
have been
erased.
3)
Load
Test
Data.
*For
convenience,
save
those chart
on
tape
as
Check
and
Adjustment
procedure
described
below
is
always
made
with the
data.
2.
D/A
converter,
CV
Check and Adjustment
Procedure
(KLM-661)
1)
Turn
off
power and
then
on
pressing
number
keys
[5]
and
[6]
at
the
same
time.
2)
Confirm
if
UrEF
(Voltage
reference)
is
displayed
and
becomes
Test
Mode
1
.
3)
Connect
a Digital
Voltmeter
to
Test
Points:
[TP-AG],
[TP-REF1]
allocated
in left
side
of the board.
GND
side
-
[TP-AG]
,
+side
-
[TP-REF1]
4)
Memorize
the
value
of
Digital
Voltmeter and then
connect
as
follows.
+side
-
[TP-CV]
5)
Adjust
VR1
to obtain the
same
value
as
one
of +side
-
[TP-REF1]
.
Remarks: Adjustment
value
is
in
range of
3.29V -
3.64V.
Note:
Test
Mode
1
cannot
be cancelled
till
being
reset.
(Power
OFF
-
ON)

Advertisement

loading