Troubleshooting
If the Power Supply LED still fails to light when the switch is connected to a different power source with a
new power cord, the power supply is probably faulty.
If a second power supply is available, install it in the second power supply bay, and contact a customer service
representative for further instructions.
Step 2
If you have a second power supply, repeat Step 1 for this power supply.
What to Do Next
If you are unable to resolve the problem or if you determine that either a power supply or backplane connector
is faulty, see

Troubleshooting the Fan Tray

To isolate a fan tray problem, follow these steps:
Procedure
Step 1
Verify that the FAN LED on the fan tray is green.
If the FAN LED is not green, see
functioning properly.
Step 2
Check to determine if the FAN LED is red or amber. If the FAN LED is red, one or more fans' tachometer
faults have exceeded the maximum limit. If the FAN LED is amber, one or more fans have encountered
tachometer faults.
Do the following:
• To ensure that the fan tray is seated properly, loosen the captive installation screws, remove the fan tray,
• Tighten all captive installation screws, and then restart the system.
• If the FAN LED is still red or amber, the system detects an individual fan failure. Contact a customer

Status LED Indicators

Refer to "System LED" section in the "Product Overview" chapter. More details will be added here later.

Contacting Cisco Customer Service

If you are unable to solve a startup problem after using the troubleshooting suggestions in this chapter, contact
a Cisco customer service representative for assistance and additional instructions. Before you call, have the
following information ready to help your service provider assist you as quickly as possible:
Contacting Cisco Customer Service, on page
and reinstall it.
service representative for instructions.
49.
Fan LED, on page 14
to determine whether or not the power subsystem is
Cisco Catalyst 9500 Series Switches Hardware Installation Guide

Troubleshooting the Fan Tray

49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents