Download Print this page

Bastl Instruments SoftPop User Manual page 7

Advertisement

A
B
INPUT
C
OUTPUT
• When using mono cables only the "left"
socket will pass a signal and the "right"
socket will be connected to ground.
• When nothing is plugged into the jack,
the "right" socket will be normalized to
ground. This can be useful for patchbay
configurations that rely on a ground
Converts socket connections in
connection, such as connecting capacitors
the patchbay to 3.5 mm jacks for
from voltage outputs to ground, which
will introduce slew to the signal.
connecting with the outside world. Use
to share audio signals, control voltages,
!!Keep in mind that any sockets
and clocks with your modular synths,
connected to any of the "right" sockets
will be grounded when the cable is
drum machine and beyond. They can
also be used to take multiple sounds
unplugged from the corresponding jack!!
from the patchbay and output them as
separate signals to be independently
processed.
• Each adapter has two sockets which
correspond to the right and left
channels of the corresponding stereo
jack (A, B or C) located on the back
of softPop. This means it is possible to
patch up to six signals in and out of the
patchbay.
• In MOST cases you will only use the
"left" socket (mono cables only use the
left channel).
PATCHBAY
SOCKET TO JACK
*Tech notes*
ADAPTERS (A, B, C)
A
B
C
VCO
– Voltage Controlled
Oscillator
normalization.
Control Voltage – direct
pitch control input (no attenuator).
1 volt per octave scaling over 2–3
octaves.
Connect an external
signal to reset the oscillator waveform.
Square wave output.
Triangle wave output.
Modulation – cutoff
control input.
Attenuate input
signal with the
modulation slider.
Normalized from
Modulation – pitch
a mix of VCO0 +
control input. Atten-
VCO1. Connect
uate input signal with
another signal
the modulation slider.
to the socket to
Normalized from the
partially override the normalization.
Track&Hold output.
Control Voltage – direct
Connect another
cutoff control input.
signal to the socket to
External signal – input
partially override the
to the filter. Can be audio or DC signals.
CV (input) -
SYNC (input) -
(output) -
(output) -
VCF
– Voltage
Controlled Filter
MOD (input) -
MOD (input) -
CV (input) -
EXT (input) -