3.12

REAR VENT CONVERSION

In order to convert the venting configuration from a top exit to a rear exit, remove components as illustrated:
EN
When reinstalling in the alternate position: Check gaskets for tears, replace if necessary to ensure a proper seal.
Outer Top
7" (178mm)
Collar
7'' (178mm)
Gasket
4'' (102mm)
Collar
4'' (102mm)
Gasket
W415-2183 / B / 02.10.17
2
3
4
5
8
6
7
4'' (102mm)
Cover Plate
4'' (102mm)
Gasket
- Remove the rear shield and the knockout
- Remove the outer top.
- Replace components 3 through 6 onto the rear of
the appliance.
- Replace components 7 through 10 onto the top of
the appliance.
- Before replacing the rear shield, slide the vent pipe through
the rear shield a few inches, secure 4'' (102mm) and
7'' (178mm) to the collars.
- Slide the rear shield along the vent pipe and re-secure to
the appliance.
- Complete vent installation.
10
9
7'' (178mm)
Cover Plate
7'' (178mm)
Gasket
Knockout
1
Rear Shield