The installation instructions describe the mechanical and electrical installation with all safety-relevant conditions and the associated technical specifications. The User manual for actuator commissioning and integration into a fieldbus system. You can also download these documents at http://www.siko-global.com/p/ag05. Block Diagram RS485...
Supply voltage of the output stage is missing. Actuator is within the programmed position window. LED2 orange Active bus operation No bus operation Table 1: LED displays AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 5 of 64...
SIKONETZ5 status word. You can define the behaviour of the actuator upon reaching the programmed window. Changing controller parameters during a positioning process does not influence the current positioning operation. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16...
The actuator drives beyond the target position by the loop length; afterwards, the set point is approached in positive direction. Positioning: loop + Loop length Positioning in positive Positioning in negative direction direction Set point Fig. 4: Positioning Loop+ AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 7 of 64...
The resulting inching speed in this example will be: Inching speed = v - Tipp * Offset inching 2 = 10 rpm * 85 % = 9 rpm The results are always rounded to integers. The minimum speed is 1 rpm. AG05 Date: 15.06.2016 Art. No. 85677 Mod.
The actual motor current cannot be stated by measuring the supply current. With cycled output stages, the supply current does not correspond to the motor current. The actual motor current can be read out via the interface or indicated on the display. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16...
Operating mode: Positioning mode Key functions: enabled For negative values to be entered, set first the value and only afterwards the arithmetical sign. The value 0 cannot be entered. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16...
Page 11
Press the key 11 times for setting the arithmetical sign. Value -500 will be displayed. Confirm by pressing the key to start positioning. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 11 of 64...
parameters Only readable see menu parameters only readable parameters Error memory see menu error memory Fig. 6: Menu selection AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 12 of 64...
Sense of rotation Selection: : i sense of rotation (cw) : e sense of rotation (ccw) (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 14 of 64...
Parameter description Parameter no. Red LED 1 function Selection: : Indication of the operating status : Off (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 16 of 64...
Page 17
Parameter description Parameter no. Display test Selection: : no display test : Start display test, pressing the key stops display test. Table 7: Visualization menu AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 17 of 64...
Table 9: Controller parameters menu 4.3.2 Readable parameters Menu Parameter Description Current output stage temperature Current control voltage Current output stage voltage Current battery voltage AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 19 of 64...
Low battery voltage 0x07 Low control electronics voltage 0x08 Excess control electronics voltage 0x09 Excess power electronics voltage 0x0A Output stage excess temperature AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 22 of 64...
Error caused by device status Input disabled due to ongoing EEPROM write access Input disabled due to active travelling job Programming lock activated AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 23 of 64...
Gear 98:1 2.05 rps v - inch Maximum speed in inching mode 1/2: Description values in rpm column Gear66:1 1 – 75 rpm Gear98:1 1 – 50 rpm AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 24 of 64...
Page 25
Changes to the calibration value are adopted for calculation of the position value via S command only after calibration. Position value = 0 + calibration value + offset value AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 25 of 64...
Page 26
negative travelling direction Spindle pitch = 0: Values refer to increments Spindle pitch > 0: Information refers to travel distance in 1/100 mm AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 26 of 64...
Page 27
(parameters 15/16) Operating mode: Speed mode: indicates the target rotational speed in rpm Value range: Gear 66:1 max. ±75 rpm Gear 98:1 max. ±50 rpm AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 27 of 64...
Page 28
10 - 100 Inching operation 2: Offset The inching speed in Inching operation 2 can be influenced via this parameter Values in percentage of parameter no. 9. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 28 of 64...
Page 29
Mode: Time monitoring "disabled=0" is only admissible for test purposes. Enable time monitoring after leaving the test mode. 1-20 = Bus Timeout values in x100 ms Service protocol: no function AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 29 of 64...
Page 30
Display: divisor Divisor by which the display accuracy is reduced compared with the measurement resolution. 0 = 1 1 = 10 2 = 100 3 = 1000 AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 30 of 64...
Page 31
Output stage voltage: output Values in 1/10 V stage Battery voltage: Voltage of Read only battery Values in 1/100 V Motor Read only Motor current: current Values in mA AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 31 of 64...
Page 32
0 = The display divisor will be applied to the application interface's target and actual positions and to the display. 1 = The display divisor will be applied to the display only. Table 13: Parameter description AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 32 of 64...
This user manual is valid with Motor controller firmware version V1.11! The PC sends a letter and additional parameters if required (ASCII). Subsequently, the AG05 sends a reply with a concluding <CR>. Parameters: 19200 / 57600 / 115200 baud, no parity, 8 data bits, 1 stop bit, no handshake...
Page 34
- Actual position within limits (only positioning mode) Bit 12 Battery voltage: Battery voltage <2.6 V Battery voltage OK Bit 13 Current limiting: Current limiting active. Current limiting not active. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 34 of 64...
Page 39
Parameter no. yy = 42: Temporary key function enable 0 = Access as defined under Key function enable 1 = Access inverted as defined under Key function enable AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 39 of 64...
Page 40
= 13: Enter spindle pitch in 1/100 mm (see chapter Parameter description Parameter no. yy = 14: Node address (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 40 of 64...
Page 41
= 34: reserved yy = 35: reserved yy = 36: LED 2 orange 0 = Off 1 = On (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 41 of 64...
Page 43
Motor brakes with programmed deceleration. Motor remains in control state! Notice! If a contouring error is pending at the time of the 'O' command, the motor will be enabled. ">" Enable motor AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 43 of 64...
Page 44
AG05 x=11105: delete primary error memory ">" Enter sense of rotation y = 0: i sense of rotation (cw) y = 1: e sense of rotation (ccw) ...
Lower software limit exceeded Set point entered exceeds limiting value Error EEPROM write access active Set point < range limit Set point > range limit Table 17: Error number encoding AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 45 of 64...
Broadcast commands are an exception, they remain always unanswered by the slave. The protocol is optimized for cyclical data exchange. The relevant data such as set point and actual value can be transferred between master and slave by a single telegram exchange. AG05 Date: 15.06.2016 Art. No. 85677 Mod.
10.3.4 Control word Control word (CW) master to slave. 10.3.5 Status word Status word (SW) slave to master. 10.3.6 Data Range for data exchange. Size: 4 bytes. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 48 of 64...
If timeout occurs during an active travel job, this will result in the Timeout error, i. e. the current travel job is cancelled. Thus, a broken cable can be detected for instance and the actuator set into a defined state. AG05 Date: 15.06.2016 Art. No. 85677 Mod.
If the travel job is not completed yet it will be cancelled. 1 = inching operation 1 As soon as this bit is set, the actuator travels the distance specified in parameter Delta Tipp. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16...
1 = acknowledgement acknowledgement The bit is set after the travel job was adopted. If bit 4 is reset in the control word, this bit will be reset as well. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 52 of 64...
Actuator travels / 1 = actuator travels stands still Bit 5 0 = Actuator is outside the position window Inpos 1 = Actuator is inside the position window AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 54 of 64...
Page 55
0 = current limiting inactive Current limiting 1 = current limiting active Motor current exceeds the value set under parameter 0x2C. Table 22: Status word speed mode SIKONETZ5 AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 55 of 64...
Access rw = read write ro = read only wo = write only AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 56 of 64...
Page 57
Parameter no. 0x08 LED 1 red Unsigned8 0 = LED 1 red Off 1 = LED 1 red On (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 57 of 64...
Page 58
Gear 98:1 value range: 1 – 50 (see chapter 8: Parameter description Parameter no. 0x15 a - rot Unsigned8 Value range 1 – 100 (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 58 of 64...
Page 59
Inpos mode Unsigned8 0 = position control 1 = short circuit of the motor windings 2 = motor activated (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 59 of 64...
Page 60
(see chapter 8: Parameter description application Parameter no. 0x60 Output stage Integer16 Temperature values in 1/10 °C temperature (see chapter 8: Parameter description Parameter no. AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 60 of 64...
Page 61
Motor current ro Integer16 Current values in mA (see chapter 8: Parameter description Parameter no. 0x65 Device code Unsigned8 0 = AG05 0x66 Display Unsigned16 Version number controller e. g. 103 corresponds to V1.03 software (see chapter 8:...
Page 62
4 = display parameters to default 5 = bus parameters to default 6 = reset error 7 = calibration 8 = delete error memory 9 = software reset AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 62 of 64...
With read commands the data range shall be set to value 0. Read command: 0x00 Node ID: 0x01 Parameter address: 0x29 Limit1 Data: 0x00 00 00 00 AG05 Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 63 of 64...