Mitsubishi Electric MELSEC-Q Series Manual page 35

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

(3) Set the [After] device and [Point], and execute the batch edit.
 Changing the start I/O number of the buffer memory
Set [Before] to U00-G2406, [After] to U02-G2406, and [Point] to 30532, and click [Replace]. U00-G2406
to U00-G32937 will be changed to U02-G2406 to U02-G32937.
Changing the start I/O number of the I/O signal
To change the input signal (X device), set [Before] to X0000, [After] to X0020, and [Point] to 32, and
click [Replace]. X0000 to X001F will be changed to X0020 to X003F.
To change the output signal (Y device), set [Before] to Y0000, [After] to Y0020, and [Point] to 32, and
click [Replace]. Y0000 to Y001F will be changed to Y0020 to Y003F.
35/35
BCN-P5999-0176-2a