Hitachi CP-X2511N Service Manual page 12

Hide thumbs Also See for CP-X2511N:
Table of Contents

Advertisement

CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
**: DC fan connectors are E801, E802,
E806 and E807.
Are
the voltage
supplied to the
NO (0V)
pin (2) of connectors**
for DC fans soon after
the button
pressed?
PWB assembly
MAIN
Observe
the voltage
waveforms at pin (1)
Correct
of connectors for DC fans**
soon after the button
is pressed.
PWB assembly
MAIN
DC fan
(failed in above check)
Blinks
is
YES
(5V or higher)
at the (1) of E814 on the
PWB assembly MAIN set to
Correct waveform is drawn below.
incorrect
Lamp does not light
What
is the state of
Light
LAMP indicator D303
during operation?
the LAMP
Not light
installation correct
Does
the voltage of
the pin #4 of E814
on the PWB assembly
MAIN change from 4.3V
to 2.8V during
warming-
up?
Change
the lamp. Does
lamp light?
Power unit (ballast)
What
Lights
is the state of
TEMP indicator
D302?
Not light
and blink
Is
the voltage
"L" during warming-
up?
PWB assembly MAIN
No
Power unit (ballast)
f ≥ 40Hz
12
*: Be sure to unplug the power cord
before measuring resistance.
Is
NG
install the Lamp
?
YES
NO
PWB assembly
Yes
Light
Lamp
Not light
Power unit (circuit)
Measure
resistance of
thermistors E1 and E2
after disconnecting
them from MAIN
board.
PWB assembly
NG
(open / short)
E1: 5 to 20kΩ
E2: 5 to 20kΩ
Thermistor
( E1 or E2 )
YES
"L" = 0V
MAIN
OK
MAIN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-x3011nEd-x45nCp-x4011nCp-x2011n