Power can not be turned on
Are
voltage
supplied at pins (3)
and (5) of E800 on the PWB
assembly MAIN in standby
mode?
(3): +15V
(5): GND
YES
Are volt-
age supplied at pins
(1), (7), (9), (11) and (19) of
E800 on the PWB assembly
MAIN in standby
mode?
(1): +5V
(7): +17V
YES
(9): GND(for +17V)
(11): +6.0V
(19): GND
Does
LAMP (D303) or
TEMP (D302) indicator light
or blink?
NO
Measure
resistance* between
pins (1) and (2) of S801 when
the lamp door is secure.
PWB assembly MAIN
*: Be sure to unplug the power cord before measuring resistance.
Measure resistance*
NO
between pins (3) and (5) of
E800.
Disconnect TSW
from power unit circuit, and
measure resistance of
TSW.
Power unit (circuit)
Measure
resistance* between pins
NO
(1) and (19),between pins (7) and (9),
and between pins (11) and (19)
of E800.
Power unit (circuit)
YES
Go to the next page
Open
Lamp door
Re-attach lamp door
Re-attach PWB assembly MAIN
11
Open
Open
Open
PWB assembly MAIN
Power unit (circuit)
Thermal switch (TSW)
PWB assembly MAIN
Power unit (circuit)

Hide quick links: