INSTALLATION PROCESS

Indicate clearly who will be responsible for switch setting.
Determination of division work
Make connection clearly between outdoor, indoor,
Preparation of contract drawings
remote controller and option.
Take account of gradient
Sleeve and insert work
of drain piping
Check model name to
Installation of indoor unit
make sure the fitting
is made correctly
Special attention to dryness,
Refrigerant piping work
cleanness and tightness
Drain pipe work
Adjust to downward gradient
Make sure airflow is sufficient
Duct work
Make sure no gaps are left where
Heat insulation work
the insulating materials are joined
Electrical work
Multiple core cable must not be used.
(connection circuits and drive circuits)
(suitable cable should be selected)
In the final check for 24hours at 3.8 MPa(38.7 kgf/cm
Airtight test
must be no drop in pressure.
The vacuum pump used must have a capacity of reaching at least
Vacuum drying
5 torr, more than 1 hour
Recharge correctly as calculated in this manual. and record the
Additional charge of refrigerant
amount of added refrigerant
Make sure there are no gaps left between the facing materials
Fit facing panels
used on the ceiling
Refer to automatic addressing flowchart
Automatic addressing of indoor unit
Preheat the crank case with the electrical heater for more than 6 hours.
Run each indoor unit in turn to make sure the pipe work
Test run adjustment
has been fitted correctly
Explain the use of the system as clearly as possible to your customer and
Transfer to customer with explanation
make sure all relevant documentation is in order
!
CAUTION
• The above list indicates the order in which the individual work
operations are normally carried out but this order may be varied
where local conditions warrants such change.
• The thickness of the piping should comply with the relevant
local and national regulations for the designed pressure 3.8MPa.
• Since R410A is a mixed refrigerant, the required additional
refrigerant must be charged in its liquid state.(If the refrigerant
is charged in its gaseous state, its composition changes and the
system will not work properly.)

OUTDOOR UNITS INFORMATION

!
CAUTION
Combination Ratio(50~200%)
Outdoor Number
Single outdoor units
Double outdoor units
Triple outdoor units
Notes : * We can guarantee the operation only within 130%
Combination. If you want to connect more than 130%
combination, please contact us and discuss the
requirement like below.
• If the operation of indoor unit is more than 130%, the airflow is
operated as low in the all indoor units.
• The number of (
) means the number of Max. connectable
indoor units, when the connected capacity of indoor units is in
the table above.
Outdoor unit foundation work
The foundation must be level even
Installation of outdoor unit
Avoid short circuits and ensure
sufficient space is allowed for service
2
) there
Connection Ratio
200%
160%
130%
Power Supply : 3Ø, 380V, 60Hz or 3Ø, 380 - 415V, 50Hz
Model Name : ARUN***LTE4
Unit
System(HP)
8
Combination Unit
ARUN080LTE4
Model
Independent Unit
ARUN080LTE4
Refrigerant
kg
7.5
Precharged Amount
lbs
16.5
Number of maxmum connectable indoor units
13(20)
kg
202 x 1
Net Weight
lbs
445 x 1
mm
(920×1,680×760) × 1
Dimensions
(WxHxD)
inch
(36-7/32 × 66-5/32 × 29-29/32) x 1 (36-7/32 × 66-5/32 × 29-29/32) x 1 (36-7/32 × 66-5/32 × 29-29/32) x 1
mm(inch)
Ø 9.52(3/8)
Piping Conections
mm(inch)
Ø 19.05(3/4)
Unit
System(HP)
14
Combination Unit
ARUN140LTE4 ARUN160LTE4 ARUN180LTE4 ARUN200LTE4
Model
Independent Unit
ARUN140LTE4 ARUN160LTE4 ARUN180LTE4 ARUN200LTE4
kg
10.5
Refrigerant
Precharged Amount
lbs
23.1
Number of maxmum connectable indoor units
23(35)
kg
245 × 1
Net Weight
lbs
540 × 1
mm
(1,240x1,680x760) x 1 (1,240×1,680×760) × 1 (1,240×1,680×760) × 1 (1,240×1,680×760) × 1
Dimensions
(48-13/16 × 66-5/32
(WxHxD)
inch
× 29-29/32) x 1
mm(inch)
Ø 12.7(1/2)
Piping Conections
mm(inch)
Ø 28.58(1-1/8)
Unit
System(HP)
22
Combination Unit
ARUN220LTE4 ARUN240LTE4 ARUN260LTE4 ARUN280LTE4
Model
ARUN120LTE4 ARUN120LTE4 ARUN140LTE4 ARUN160LTE4
Independent Unit
ARUN100LTE4 ARUN120LTE4 ARUN120LTE4 ARUN120LTE4
kg
7.5 x 2
Refrigerant
Precharged Amount
lbs
16.5 x 2
Number of maxmum connectable indoor units
35(44)
kg
208 x 2
Net Weight
lbs
458 x 2
mm
(920×1,680×760) x 2 (920×1,680×760) x 2
Dimensions
(WxHxD)
(36-7/32 × 66-5/32 ×
inch
29-29/32) x 2
mm(inch)
Ø 15.88(5/8)
Piping Conections
mm(inch)
Ø 28.58(1-1/8)
Unit
System(HP)
30
Combination Unit
ARUN300LTE4 ARUN320LTE4 ARUN340LTE4 ARUN360LTE4
Model
ARUN180LTE4 ARUN200LTE4 ARUN200LTE4 ARUN200LTE4
Independent Unit
ARUN120LTE4 ARUN120LTE4 ARUN140LTE4 ARUN160LTE4
kg
10.5 + 7.5
Refrigerant
Precharged Amount
lbs
23.1 + 16.5
Number of maxmum connectable indoor units
49(60)
kg
(280 × 1) + (208 × 1) (280 × 1) + (208 × 1) (280 × 1) + (245 × 1) (280 × 1) + (245 × 1)
Net Weight
lbs
(617 × 1) + (458 × 1) (617 × 1) + (458 × 1) (617 × 1) + (540 × 1) (617 × 1) + (540 × 1)
(1,240×1,680×760) × 1
mm
+ (920×1,680×760) × 1
Dimensions
(48-13/16 × 66-5/32 × 29-
(WxHxD)
inch
29/32) x 1 + (36-7/32 × 66-
5/32 × 29-29/32) x 1
mm(inch)
Ø 19.05(3/4)
Piping Conections
mm(inch)
Ø 34.9(1-3/8)
Unit
2 Outdoor Unit
System(HP)
38
Combination Unit
ARUN380LTE4 ARUN400LTE4 ARUN420LTE4 ARUN440LTE4
ARUN200LTE4 ARUN200LTE4 ARUN180LTE4 ARUN200LTE4
Model
Independent Unit
ARUN180LTE4 ARUN200LTE4 ARUN140LTE4 ARUN140LTE4
Refrigerant
kg
10.5 x 2
Precharged Amount
lbs
23.1 x 2
Number of maxmum connectable indoor units
61(64)
kg
280 x 2
Net Weight
lbs
617 x 2
mm
(1,240×1,680×760) x 2 (1,240×1,680×760) x 2
Dimensions
(48-13/16 × 66-
(WxHxD)
inch
5/32 × 29-29/32)
x 2
mm(inch)
Ø 19.05(3/4)
Piping Conections
mm(inch)
Ø 41.3(1-5/8)
1 Outdoor Unit
10
12
ARUN100LTE4
ARUN120LTE4
ARUN100LTE4
ARUN120LTE4
7.5
7.5
16.5
16.5
16(25)
20(30)
208 x 1
208 x 1
458 x 1
458 x 1
(920×1,680×760) × 1
(920×1,680×760) × 1
Ø 9.52(3/8)
Ø 12.7(1/2)
Ø 22.2(7/8)
Ø 28.58(1-1/8)
1 Outdoor Unit
16
18
20
10.5
10.5
10.5
23.1
23.1
23.1
26(40)
29(45)
32(50)
245 × 1
280 × 1
280 × 1
540 × 1
617 × 1
617 × 1
(48-13/16 × 66-5/32
(48-13/16 × 66-5/32
(48-13/16 × 66-5/32
× 29-29/32) x 1
× 29-29/32) x 1
× 29-29/32) x 1
Ø 12.7(1/2)
Ø 15.88(5/8)
Ø 15.88(5/8)
Ø 28.58(1-1/8)
Ø 28.58(1-1/8)
Ø 28.58(1-1/8)
2 Outdoor Unit
24
26
28
7.5 x 2
10.5 + 7.5
10.5 + 7.5
16.5 x 2
23.1 + 16.5
23.1 + 16.5
39(48)
42(52)
45(56)
208 x 2
(245 × 1) + (208 × 1) (245 × 1) + (208 × 1)
458 x 2
(540 × 1) + (458 × 1) 540 × 1) + (458 × 1)
(1,240x1,680x760) x 1
(1,240×1,680×760) × 1
+ (920x1,680x760) x 1
+ (920×1,680×760) × 1
(48-13/16 × 66 -5/32 × 29 -
(48-13/16 × 66-5/32 × 29-
(36-7/32 × 66-5/32 ×
29/32) x 1 + (36-7/32 × 66 -
29/32) x 1 + (36-7/32 × 66-
29-29/32) x 2
5/32 × 29-29/32) x 1
5/32 × 29-29/32) x 1
Ø 15.88(5/8)
Ø 19.05(3/4)
Ø 19.05(3/4)
Ø 34.9(1-3/8)
Ø 34.9(1-3/8)
Ø 34.9(1-3/8)
2 Outdoor Unit
32
34
36
10.5 + 7.5
10.5 × 2
10.5 × 2
23.1 + 16.5
23.1 × 2
23.1 × 2
52(64)
55(64)
58(64)
(1,240×1,680×760) × 1
(1,240×1,680×760) x 2 (1,240×1,680×760) x 2
+ (920×1,680×760) × 1
(48-13/16 × 66-5/32 × 29-
(48-13/16 × 66-5/32
(48-13/16 × 66-5/32 ×
29/32) x 1 + (36-7/32 × 66-
× 29-29/32) x 2
29-29/32) x 2
5/32 × 29-29/32) x 1
Ø 19.05(3/4)
Ø 19.05(3/4)
Ø 19.05(3/4)
Ø 34.9(1-3/8)
Ø 34.9(1-3/8)
Ø 41.3(1-5/8)
3 Outdoor Unit
40
42
44
ARUN100LTE4 ARUN100LTE4
10.5 x 2
(10.5 × 2) + 7.5 (10.5 × 2) + 7.5
23.1 x 2
(23.1 × 2) + 16.5 (23.1 × 2) + 16.5
64
64
64
280 x 2
(280 × 1) + (245 x 1) + (208 × 1) (280 × 1) + (245 x 1) + (208 × 1)
617 x 2
(617 × 1) + (540 x 1) + (458 × 1) (617 × 1) + (540 x 1) + (458 × 1)
(1,240×1,680×760) × 2
(1,240×1,680×760) × 2
+ (920×1,680×760) × 1
+ (920×1,680×760) × 1
(48-13/16 × 66-
(48-13/16 × 66-5/32 × 29-
(48-13/16 × 66-5/32 × 29-
5/32 × 29-29/32)
29/32) x 2 + (36-7/32 ×
29/32) x 2 + (36-7/32 × 66-
x 2
66-5/32 × 29-29/32) x 1
5/32 × 29-29/32) x 1
Ø 19.05(3/4)
Ø 19.05(3/4)
Ø 19.05(3/4)
Ø 41.3(1-5/8)
Ø 41.3(1-5/8)
Ø 41.3(1-5/8)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents