Table 31 UCS C240 M3 LFF 450 W Power Supply Specifications (continued)
Description
Power supply efficiency
The general power specifications for the C240 M3 LFF server 650 W power supply are listed in
Table 32 UCS C240 M3 LFF 650 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for the
power supply
Power supply output voltage
Power supply efficiency
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
Specification
CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Specification
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
7.6 A maximum @ 100 VAC
3.65 A maximum @ 208 VAC
11 A peak at 35° C, 208 VAC
650 W
Main power: 12 VDC
Standby power: 12 VDC
CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.