Alarms
When an alarm occurs, an alarm icon will appear on the display together with an ID code and the description of the alarm in the selected language.
If the page navigation buttons are pressed, the pop-up window with the alarm indications momentarily disappear and then reappear after a few seconds.
The red LED next to the alarm icon on the front panel will blink for as long as an alarm is active. If enabled, the local and remote acoustic alarms are
activated.
The alarms can be reset by pressing the OFF button.
If the alarm is not reset, it means that its cause persists.
If one or more alarms occur, the behaviour of the ATL6.. will depend on the alarm property setting.
Alarm properties
Various properties can be assigned to each alarm, including the user alarms (User Alarms, Uax):
Enabled alarm – General alarm enable. If not enabled, it is as if it does not exist.
AUT only – The alarm may only be generated when ATL is in automatic mode.
Retaining alarm – This remains stored even if its cause was removed.
Global alarm A – This activates the outputs assigned to this function.
Global alarm B – This activates the outputs assigned to this function.
Block BRK1 – controls are no longer sent to breaker BRK1 when the alarm occurs.
Block BRK2 – as above referred to breaker BRK2.
Siren – Activates the output assigned to this function as configured in the alarms table.
Inhibit – The alarm may be temporarily deactivated by activating a programmable input with the alarm inhibit function.
Modem – The alarm will be sent via modem (SMS or FTP).
No LCD – The alarm is normally managed but not shown on the display.
Alarms table
The following table shows the alarm codes, together with a description and the default properties of each one.
CODE
A01 Battery voltage too low
A02 Battery voltage too high
A03 BRK1 breaker timeout
A04 BRK2 breaker timeout
A06 Incorrect phase sequence Line SRC1
A07 Incorrect phase sequence Line SRC2
A09 Load not powered timeout
A10 Local battery charger failure
A11 Genset battery charger 1 failure
A12 Genset battery charger 2 failure
A14 Emergency
A15 BRK1 breaker protection trip
A16 BRK2 breaker protection trip
A18 BRK1 breaker withdrawn
A19 BRK2 breaker withdrawn
A21 SRC1 genset line not available
A22 SRC2 genset line not available
A24 Maintenance hours SRC1
A25 Maintenance hours SRC2
A27 Maintenance operations BRK1
A28 Maintenance operations BRK2
A30 Auxiliary voltage breaker alarm
A32 Tie breaker TB1 timeout
A35 TB1 tie breaker protection trip
A38 TB1 tie breaker withdrawn
UA1..8 User alarms