Step
1.
Enter system view.
2.
Enter CWMP view.
3.
Configure the CPE
username for connection to
the CPE.
4.
Configure the CPE
password for connection to
the CPE.

Configuring the CWMP connection interface

The CWMP connection interface is the interface that the CPE uses to communicate with the ACS.
The CPE sends the IP address of this interface in the Inform messages and the ACS replies to this IP
address for setting up a CWMP connection.
If the interface that connects the CPE to the ACS is the only Layer 3 interface that has an IP address
on the device, you do not need to specify the CWMP connection interface. If multiple Layer 3
interfaces are configured, specify the CWMP connection interface to make sure the IP address of the
interface that connects to the ACS is sent to the ACS for setting up CWMP connection.
To configure a CWMP connection interface:
Step
1.
Enter system view.
2.
Enter CWMP view.
3.
Set the interface that
connects the CPE to the
ACS.

Sending Inform messages

You must configure the Inform message sending parameter on the CPE to initiate a connection to the
ACS.
To configure the CPE to periodically send Inform messages:
Step
1.
Enter system view.
2.
Enter CWMP view.
3.
Enable the periodic sending
of Inform messages.
Command
system-view
cwmp
cwmp cpe username username
cwmp cpe password [ cipher |
simple ] password
Command
system-view
cwmp
cwmp cpe connect interface
interface-type interface-number
Command
system-view
cwmp
cwmp cpe inform interval
enable
209
Remarks
N/A
N/A
By default, no CPE username is
configured for connection to the
CPE.
Optional.
You can specify a username
without a password that is used in
the authentication. If so, the
configuration on the ACS and that
on the CPE must be the same.
By default, no CPE password is
configured for connection to the
CPE.
Remarks
N/A
N/A
By default, the interface for
connecting the CPE to the ACS is
not configured.
Remarks
N/A
N/A
By default, the function is
disabled.