Spectrum 3440 Product Manual

Temp / rh / co2 hand-held meter

Advertisement

Quick Links

Temp / RH / CO
2
Hand-Held Meter
PRODUCT MANUAL
Item # 3440

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3440 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Spectrum 3440

  • Page 1 Temp / RH / CO Hand-Held Meter PRODUCT MANUAL Item # 3440...
  • Page 2: Table Of Contents

    CONTENTS Specifications Battery LCD Display Keypad Operation Troubleshooting Warranty CE Declaration of Conformity Thank you for purchasing the Temp/RH/CO Hand-Held Meter. With an NDIR (non-dispersive infrared) CO sensor, this unit is stable for long-term monitoring. Please read this manual thoroughly before using your meter. Specifications Range 0 to 5000 ppm...
  • Page 3: Battery

    Battery Install the 4 AA batteries into the battery compartment on the rear and make sure they are in correct polarity. When the battery voltage gets low, the battery icon and “Lob” will appear on the LCD, and the beeper will sound (press any key to stop the beeps).
  • Page 4: Operation

    Operation Power On/Off Press the On/Off/Set key to turn the meter on or off. During warm-up, it will perform a 30 second countdown, then will dis- play current CO , temperature, and humidity. The meter turns off automatically after 20 minutes of inactivity. To bring the meter to non-sleep mode, press and hold SET and HOLD for 2 to 3 seconds.
  • Page 5 Data Hold The data hold function works in both IR and probe modes. In IR measurement, just release MEAS button, the meter stops measuring and holds the last reading until next measurement is taken or power off. To hold the data in probe measure- ment, release MEAS button and wait until it gets the stable reading.
  • Page 6 concentration. It is suggested to do a manual calibration regularly to maintain good accuracy. The calibration should be done during sunny weather in fresh outdoor air that is well-ventilated. CAUTION: Do not calibrate the meter in the air with an un- known CO concentration.
  • Page 7: Troubleshooting

    Troubleshooting Unable to power on Press the On/Off/Set key for more than 0.3 seconds and try again. Check whether the batteries have good contact and the correct polarity. Readings do not change Check whether data hold function was activated (HOLD icon at the left top).
  • Page 8: Warranty

    This product is warranted to be free from defects in material or work- manship for one year from the date of purchase. During the warranty period Spectrum will, at its option, either repair or replace products that prove to be defective. This warranty does not cover damage due to...